{"product_id":"field-control-processor-module-yokogawa-nfcp501-w15-s1","title":"Field Control Processor Module | Yokogawa NFCP501-W15 S1","description":"\u003ch2\u003eYokogawa NFCP501-W15 S1 Field Control Processor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa NFCP501-W15 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNFCP501\u003c\/strong\u003e Field Control Processor Module, operates as a dedicated hardware component for executing regulatory and sequence control, logic chart processing, and arithmetic calculations within CENTUM VP Vnet\/IP Field Control Stations. It provides deterministic execution of control loops and seamless switchover in a redundant Pair \u0026amp; Spare configuration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa NFCP501-W15 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSlot-mounted module for FCU baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC (Operating), -20 to 70 degC (Storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e5.5 VDC, 2.0 A to 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleType\u003c\/td\u003e\n\u003ctd\u003eField Control Processor (FCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetworkInterface\u003c\/td\u003e\n\u003ctd\u003eDual-redundant 1000Base-T Vnet\/IP Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessorArchitecture\u003c\/td\u003e\n\u003ctd\u003ePair \u0026amp; Spare (Dual CPU redundancy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlFunctionCapacity\u003c\/td\u003e\n\u003ctd\u003eStandard control loops, sequence tables, logic charts, SFC blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemoryCapacity\u003c\/td\u003e\n\u003ctd\u003eDefined by -W15 suffix (high-capacity control database)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulationResistance\u003c\/td\u003e\n\u003ctd\u003e≥10 MΩ at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstandingVoltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC between terminals and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Technical Features\u003c\/h3\u003e\n\u003cp\u003eThe NFCP501-W15 S1 supports 4-20 mA HART loop protocol interfaces for analog field devices, ensuring accurate channel-to-channel isolation for dense control loop topologies. The module incorporates cold junction compensation (CJC) for precise temperature measurement and supports deterministic Vnet\/IP communications with dual-redundant 1 Gbps links.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the NFCP501-W15 S1 support hot-swapping while in operation?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module supports hot-swap maintenance without process interruption, maintaining Pair \u0026amp; Spare synchronization during the replacement procedure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the expected switchover time in case of a CPU discrepancy?\u003c\/strong\u003e\u003cbr\u003eA: The Pair \u0026amp; Spare architecture detects calculation mismatches and performs a seamless switchover to the spare CPU within milliseconds, preventing control loop disruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can firmware be updated without taking the FCS offline?\u003c\/strong\u003e\u003cbr\u003eA: Firmware updates are supported via the control network while the module continues deterministic execution; proper synchronization with the redundant CPU is required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the NFCP501-W15 S1 into the designated FCU slot, ensuring the module is fully seated and the latching mechanism engages.\u003c\/li\u003e\n\u003cli\u003eMaintain separate routing of power and network cables to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect both redundant Vnet\/IP Ethernet links and verify link status LEDs.\u003c\/li\u003e\n\u003cli\u003eGround the module shield to the FCU chassis to ensure proper EMI protection.\u003c\/li\u003e\n\u003cli\u003eAvoid placing the module near heat sources; allow adequate airflow within the cabinet for ambient temperature control.\u003c\/li\u003e\n\u003cli\u003eConfirm module pairing with the redundant CPU in the system configuration before initiating control operations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44219317649496,"sku":"NFCP501-W15 S1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/NFCP501-W15S1-2.jpg?v=1781144633","url":"https:\/\/www.industriaxplc.com\/ar\/products\/field-control-processor-module-yokogawa-nfcp501-w15-s1","provider":"IndustriaX Limited","version":"1.0","type":"link"}