{"product_id":"esb-bus-node-units-anb10d-425-cu2t-s2-yokogawa","title":"ESB Bus Node Units | ANB10D-425\/CU2T S2 | Yokogawa","description":"\u003ch2\u003eYokogawa ANB10D-425\/CU2T S2 ESB Bus Node Units\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-425\/CU2T\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D\u003c\/strong\u003e ESB Bus Node Unit, operates as a dedicated hardware component for high-speed I\/O signal interfacing within CENTUM VP and CENTUM CS 3000 DCS platforms. It provides dual-redundant power and communication paths to maintain continuous field bus operations.\u003c\/p\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10D-425\/CU2T S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm × 221.5 mm × 150.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e230 VA \/ 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputVoltage\u003c\/td\u003e\n\u003ctd\u003e220–240 V AC, ±15% \/ +10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz ±3 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual-redundant power supply (PW482 modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaxIONodes\u003c\/td\u003e\n\u003ctd\u003eUp to 13 nodes per FCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOModuleSlots\u003c\/td\u003e\n\u003ctd\u003e8 slots for FIO\/communication modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusTermination\u003c\/td\u003e\n\u003ctd\u003eConnector Unit with integrated terminator (\/CU2T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ANB10D supports 4–20 mA HART loop connectivity and ensures \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e to prevent cross-talk between analog and digital signals. The node unit maintains \u003cstrong\u003ecold junction compensation (CJC)\u003c\/strong\u003e for thermocouple measurements and supports FOUNDATION Fieldbus communication for deterministic process control integration. Firmware updates are compatible across Style 2 revisions without interruption to the redundant ESB bus operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Can I hot-swap I\/O modules without shutting down the ESB bus?\u003cbr\u003eA: Yes, modules are hot-swappable within the dual-redundant configuration; ensure proper module seating and follow rack isolation procedures.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: What is the maximum current load on the ESB backplane per node?\u003cbr\u003eA: The backplane supports the cumulative current of eight standard FIO modules plus two SB401 bus interfaces within rated specifications of the PW482 power modules.\u003c\/p\u003e\n\u003cp\u003eQ: VnA: Are firmware updates for the ANB10D-425\/CU2T backward-compatible?\u003cbr\u003eA: Updates within the Style 2 revision maintain dual-redundant functionality and module communication integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit in a standard 19-inch rack using M5 × 4 screws.\u003c\/li\u003e\n\u003cli\u003eEnsure the ESB bus terminator (\/CU2T) is installed on the last node of the network.\u003c\/li\u003e\n\u003cli\u003eRoute power and communication cables separately to reduce EMI interference.\u003c\/li\u003e\n\u003cli\u003eConnect the grounding point on the chassis to facility earth to maintain EMC compliance.\u003c\/li\u003e\n\u003cli\u003eAvoid obstructing front and rear airflow; maintain minimum 50 mm clearance around the chassis.\u003c\/li\u003e\n\u003cli\u003eVerify dual-redundant power supply connection before commissioning the I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44202978607192,"sku":"ANB10D-425-CU2T S2","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10D-425-CU2TS2.jpg?v=1780881514","url":"https:\/\/www.industriaxplc.com\/ar\/products\/esb-bus-node-units-anb10d-425-cu2t-s2-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}