{"product_id":"esb-bus-node-unit-yokogawa-anb10d-410-ndel","title":"ESB Bus Node Unit Yokogawa ANB10D-410\/NDEL","description":"\u003ch2\u003eYokogawa ANB10D-410\/NDEL ESB Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for signal transmission between Field Control Units and distributed I\/O modules in CENTUM VP and CENTUM CS 3000 systems, the \u003cstrong\u003eYokogawa ANB10D-410\/NDEL\u003c\/strong\u003e (\u003cstrong\u003eANB10D\u003c\/strong\u003e ESB Bus Node Unit) provides direct physical and electrical execution of ESB bus communications while supporting redundant power and interface configurations.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp;Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eANB10D\u003c\/td\u003e\n\u003ctd\u003eESB Bus Node Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-4\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB bus interface and dual-redundant power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e100 - 120 VAC power input type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/NDEL\u003c\/td\u003e\n\u003ctd\u003eProject-specific option designation as defined by system configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardwareSpecifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10D-410\/NDEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 5.7 kg (excluding I\/O modules and cables)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 degC (operation), -20 to 70 degC (storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eMax. 100 VA at 100 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerSupplyVoltage\u003c\/td\u003e\n\u003ctd\u003e100 - 120 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 FIO series I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eDual-redundant ESB Bus Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Modules\u003c\/td\u003e\n\u003ctd\u003eDual PW481 power supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Modules\u003c\/td\u003e\n\u003ctd\u003eDual SB401 ESB Bus Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e19-inch rack mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e10 % to 90 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC between power terminals and grounding terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e20 Mohm minimum at 500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe node unit architecture supports isolation strategies commonly applied within distributed process control environments. Channel segregation minimizes electrical coupling between connected I\/O circuits, reducing interference propagation through field wiring. When integrated with compatible FIO modules, the platform supports transmission of standard 4-20 mA process signals and communication structures used within HART-enabled instrumentation networks. Compatibility with FOUNDATION Fieldbus and Profibus PA system architectures depends on the connected field interface modules and associated controller configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ANB10D-410\/NDEL support online replacement of I\/O modules?\u003cbr\u003eA: The unit is designed to allow I\/O module replacement while the node remains operational, subject to the limitations and procedures defined for the installed module type.\u003c\/p\u003e\n\u003cp\u003eQ: How many I\/O modules can be installed in one node unit?\u003cbr\u003eA: A maximum of 8 FIO series I\/O modules can be installed.\u003c\/p\u003e\n\u003cp\u003eQ: What redundancy functions are integrated into the hardware?\u003cbr\u003eA: The unit contains dual PW481 power supply modules and dual SB401 ESB bus interface modules, providing redundant power and communication paths.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the node unit in a properly grounded 19-inch control cabinet.\u003c\/li\u003e\n\u003cli\u003eSeparate ESB communication cables from power wiring to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to plant grounding standards and maintain a single-point shield grounding method where required.\u003c\/li\u003e\n\u003cli\u003eVerify correct seating of PW481 and SB401 modules before energizing the rack.\u003c\/li\u003e\n\u003cli\u003eMaintain ambient conditions within the specified temperature and humidity ranges.\u003c\/li\u003e\n\u003cli\u003eConfirm adequate rack ventilation and unobstructed airflow around installed modules.\u003c\/li\u003e\n\u003cli\u003ePerform insulation and grounding verification before connecting field wiring to associated I\/O modules.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44186842923096,"sku":"ANB10D-410\/NDEL","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10D-410NDEL-2.jpg?v=1780625165","url":"https:\/\/www.industriaxplc.com\/ar\/products\/esb-bus-node-unit-yokogawa-anb10d-410-ndel","provider":"IndustriaX Limited","version":"1.0","type":"link"}