{"product_id":"discrete-input-module-modicon-x80-schneider-electric-bmxddi3202k","title":"Discrete Input Module Modicon X80 Schneider Electric BMXDDI3202K","description":"\u003ch1\u003eSchneider Electric BMXDDI3202K Discrete Input Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for acquisition of 24 V DC discrete field signals in Modicon X80 I\/O architecture, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric BMXDDI3202K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eBMXDDI3202K\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDiscrete Input Module) provides direct physical\/electrical execution within Modicon M340 and X80 backplane systems. The module processes 32 isolated positive logic inputs with sink-type current detection and channel-level diagnostics.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric BMXDDI3202K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.112 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 3.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eIsolated, current sink (positive logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e2.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Supply Range\u003c\/td\u003e\n\u003ctd\u003e19 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiltering Time\u003c\/td\u003e\n\u003ctd\u003e4 ms typical, 7 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eModicon X80 platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePLC Backplane Communication and Signal Conditioning Behavior\u003c\/h3\u003e\n\u003cp\u003eThe Modicon X80 architecture associated with BMXDDI3202K implements deterministic backplane communication for cyclic I\/O refresh across distributed input modules. Signal conditioning is performed via internal filtering stages with fixed 4 ms digital debounce logic, ensuring suppression of transient switching noise on 24 V DC field wiring. The module supports channel-level isolation to reduce cross-channel electrical coupling under high-density cabling layouts.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the BMXDDI3202K inputs be paralleled for higher current sensing?\u003cbr\u003eA: No. Input paralleling is not supported. Each channel operates with independent isolation and fixed impedance input circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: What is the internal response delay of input signal detection?\u003cbr\u003eA: The module uses a 4 ms typical filtering time, with a maximum of 7 ms depending on signal stability.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swap insertion on the backplane?\u003cbr\u003eA: Hot-swap capability depends on the Modicon X80 rack configuration. Electrical isolation exists at channel level, but system-level insertion rules apply.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eField wiring shall maintain separation between input signal cables and power conductors to minimize inductive coupling. Use shielded twisted pair conductors for long cable runs and terminate shields at a single-point earth reference. Ensure 24 V DC sensor supply remains within 19 to 30 V DC range under full load conditions. Verify correct polarity for positive logic sink configuration prior to energization. Maintain secure DIN rail seating and backplane connector alignment to avoid intermittent channel faults.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44242118574168,"sku":"BMXDDI3202K","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXDDI3202K-3.jpg?v=1781513067","url":"https:\/\/www.industriaxplc.com\/ar\/products\/discrete-input-module-modicon-x80-schneider-electric-bmxddi3202k","provider":"IndustriaX Limited","version":"1.0","type":"link"}