{"product_id":"digital-contact-output-module-yokogawa-adm52","title":"Digital Contact Output Module | Yokogawa ADM52","description":"\u003ch2\u003eYokogawa ADM52 Digital Contact Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete field actuation in CENTUM CS 3000 and μXL systems, the \u003cstrong\u003eYokogawa ADM52\u003c\/strong\u003e (\u003cstrong\u003eADM52\u003c\/strong\u003e Digital Contact Output Module) provides direct physical\/electrical execution of 16-channel contact output signals through a 32-point connector interface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eADM52\u003c\/strong\u003e: Standard 16-channel digital\/contact output card\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNo additional suffixes or variants defined in source data\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase series ADM52\u003c\/strong\u003e: Legacy Yokogawa Digital Contact Output Module family\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ADM52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan \/ Singapore\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 22.9 cm x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eContact output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e32-point high-density connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Isolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system isolation withstanding up to 1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSlide-in rack module compatible with RIO nests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa Channel Isolation and Contact Switching Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach channel is electrically isolated to prevent backfeed or cross-channel interference.\u003c\/li\u003e\n\u003cli\u003eDry contact output is suitable for driving low-current relays and alarm indicators.\u003c\/li\u003e\n\u003cli\u003eHigh-density connector ensures stable mechanical and electrical connection in vibration-prone industrial environments.\u003c\/li\u003e\n\u003cli\u003eInternal surge protection and isolation support enduring operation under transient voltage conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the ADM52 module handle simultaneous switching of all 16 outputs at maximum current?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, each channel is rated for 100 mA and can switch simultaneously provided total thermal limits are respected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does the module support hot-swapping in an operational RIO rack?\u003c\/strong\u003e\u003cbr\u003eA2: No. The ADM52 is not designed for hot-swap insertion; power must be removed before installation or removal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum voltage tolerance per contact channel?\u003c\/strong\u003e\u003cbr\u003eA3: The output contacts are rated for 30 VDC nominal, with isolation tolerances of 1500 V AC between channels and system circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify correct orientation of module slide rails before insertion into RIO rack\u003c\/li\u003e\n\u003cli\u003eEnsure connector pins are aligned; excessive force may damage high-density connector\u003c\/li\u003e\n\u003cli\u003eGround RIO rack according to standard industrial grounding practices\u003c\/li\u003e\n\u003cli\u003eAvoid routing high-current power cables parallel to digital output signal lines\u003c\/li\u003e\n\u003cli\u003eInspect mechanical latch and locking mechanism to maintain module retention under vibration\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44165732958296,"sku":"ATI3S-001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ATI3S-001-2_1a84f230-b668-406f-ab55-8d1b0492bd34.jpg?v=1780369380","url":"https:\/\/www.industriaxplc.com\/ar\/products\/digital-contact-output-module-yokogawa-adm52","provider":"IndustriaX Limited","version":"1.0","type":"link"}