{"product_id":"ci858-3bse018135r1-abb-ac-800m-drivebus-communication-interfaces","title":"CI858 3BSE018135R1 ABB AC 800M DriveBus Communication Interfaces","description":"\u003ch2\u003eABB CI858 DriveBus Communication Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for DriveBus communication between ABB Drives, ABB Special I\/O units, and an AC 800M controller, the \u003cstrong\u003eABB CI858\u003c\/strong\u003e (\u003cstrong\u003eCI858\u003c\/strong\u003e DriveBus Communication Interface) provides the controller-side interface for ABB DriveBus networks. The interface operates as a DriveBus master at 8 Mbit\/s and receives its power through the CEX-Bus from the processor unit.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI858\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE018135R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDriveBus Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eABB DriveBus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e8 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Together with HI Controller\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units on CEX-Bus\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eOptical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eVia CEX-Bus from processor unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e24 V Consumption, Typical\u003c\/td\u003e\n\u003ctd\u003e200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529, IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Including Base\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDriveBus Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CI858 provides the DriveBus communication path between an AC 800M controller and compatible ABB Drives and ABB Special I\/O units. The interface operates as the network master and supports an 8 Mbit\/s transmission rate.\u003c\/p\u003e\n\u003cp\u003eABB designed DriveBus for sectional drive applications, including ABB rolling mill drive systems and paper machine control systems. Therefore, the CI858 handles the controller-side communication interface without requiring a separate external power source.\u003c\/p\u003e\n\u003cp\u003eThe CI858 receives operating power through the CEX-Bus from the processor unit. Its typical 24 V consumption is 200 mA. The interface supports hot swap, while the specified configuration provides no line redundancy or module redundancy.\u003c\/p\u003e\n\u003cp\u003eThe optical connector provides the physical DriveBus connection. The CEX-Bus supports a maximum of two CI858 units according to the supplied technical data.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Control and Drive Interface\u003c\/h3\u003e\n\u003cp\u003eThe CI858 belongs to the ABB AC 800M communication interface architecture and uses the CEX-Bus for internal controller communication. Consequently, installation must maintain the required CEX-Bus connection between the processor unit and communication interface.\u003c\/p\u003e\n\u003cp\u003eFor DriveBus applications, the communication interface should be configured according to the connected ABB Drive system and controller application. The supplied data specifies DriveBus at 8 Mbit\/s and identifies the CI858 as the master device.\u003c\/p\u003e\n\u003cp\u003eThis interface does not use an external power supply. Instead, the processor unit supplies the CI858 through the CEX-Bus, while the optical connector provides the external communication path.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CI858 require an external power supply?\u003cbr\u003eA: No. The CI858 receives power from the AC 800M processor unit through the CEX-Bus. The typical 24 V consumption is 200 mA.\u003c\/p\u003e\n\u003cp\u003eQ: What communication protocol and transmission speed does the CI858 use?\u003cbr\u003eA: The CI858 uses ABB DriveBus and operates at a specified transmission speed of 8 Mbit\/s.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CI858 support hot swap and redundant operation?\u003cbr\u003eA: The CI858 supports hot swap. The supplied specifications state that neither line redundancy nor module redundancy is provided.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CI858 within the specified operating temperature range of 0 to +55 deg C.\u003c\/li\u003e\n\u003cli\u003eMaintain the IP20 installation environment and provide suitable enclosure protection for the complete control assembly.\u003c\/li\u003e\n\u003cli\u003eConnect the CI858 to the AC 800M CEX-Bus according to the controller hardware configuration.\u003c\/li\u003e\n\u003cli\u003eDo not add an external power supply to the CI858 when using the specified CEX-Bus power arrangement.\u003c\/li\u003e\n\u003cli\u003eConnect the optical DriveBus interface using compatible optical cabling and approved connectors.\u003c\/li\u003e\n\u003cli\u003eRoute communication cabling separately from high-current power conductors where practical to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cabinet grounding and bonding for the controller enclosure and associated drive equipment.\u003c\/li\u003e\n\u003cli\u003eVerify the DriveBus master configuration before placing connected ABB Drives or Special I\/O units into operation.\u003c\/li\u003e\n\u003cli\u003eConfirm the CEX-Bus configuration when installing more than one CI858, as the supplied specification permits a maximum of two units on the CEX-Bus.\u003c\/li\u003e\n\u003cli\u003eObserve the specified storage range of -40 to +70 deg C when storing the module before installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623584657496,"sku":"CI858 3BSE018135R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI858-3BSE018135R1-3_1200x1200_54cf8300-6801-4d56-be2a-ae40023ba65d.jpg?v=1787127088","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ci858-3bse018135r1-abb-ac-800m-drivebus-communication-interfaces","provider":"IndustriaX Limited","version":"1.0","type":"link"}