{"product_id":"ci854bk01-ci854b-tp854-abb-profibus-dp-communication-interface","title":"CI854BK01 CI854B+TP854 ABB PROFIBUS DP Communication Interface","description":"\u003ch2\u003eABB CI854BK01 PROFIBUS DP Communication Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for PROFIBUS DP-V1 master communication in System 800xA, the \u003cstrong\u003eABB CI854BK01\u003c\/strong\u003e (\u003cstrong\u003eCI854B\u003c\/strong\u003e PROFIBUS DP Communication Interface) provides two PROFIBUS ports for line redundancy and supports redundant master configurations. The package includes the CI854B communication interface and TP854 baseplate.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Model\u003c\/td\u003e\n\u003ctd\u003eCI854BK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCI854B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Configuration\u003c\/td\u003e\n\u003ctd\u003eCI854B + TP854 Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Mode\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFIBUS Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster Module Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEX Bus Capacity\u003c\/td\u003e\n\u003ctd\u003eMaximum 12 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSystem 800xA 6.0.3.2 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompact Control Builder\u003c\/td\u003e\n\u003ctd\u003e6.0.0-2 and later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with HI Controller\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI854BK01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in provided data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eCI854B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003ctd\u003eTP854\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS DP-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e9.6 to 12000 kbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e9-pin female DB connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units on CEX Bus\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical 24 V Consumption\u003c\/td\u003e\n\u003ctd\u003e190 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2 according to IEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN 60529 and IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Including Base\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePROFIBUS DP and CEX Bus Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CI854B connects an AC 800M controller to PROFIBUS DP field devices through two physical PROFIBUS ports. Each port supports transmission rates from 9.6 to 12000 kbit\/s.\u003c\/p\u003e\n\u003cp\u003eThe interface supports line redundancy by using both PROFIBUS ports. In addition, two CI854B modules can provide PROFIBUS master redundancy. This redundant master configuration can operate together with CPU redundancy and CEX Bus redundancy using BC810.\u003c\/p\u003e\n\u003cp\u003eThe CI854B mounts on a DIN rail through the TP854 baseplate. It communicates with the AC 800M controller through the CEX Bus and can interface with S800 I\/O and other PROFIBUS DP or DP-V1 I\/O systems.\u003c\/p\u003e\n\u003cp\u003eThe PROFIBUS network requires termination at the two outermost nodes. Connectors with integrated termination can provide this function. The terminating connector must remain connected and powered for correct termination operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many PROFIBUS ports does the CI854B provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CI854B provides two PROFIBUS ports. The two ports support line redundancy within the PROFIBUS network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can two CI854B modules provide master redundancy?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Two CI854B communication interface modules can be configured for PROFIBUS master redundancy. The configuration can also operate with CPU redundancy and CEX Bus redundancy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the typical 24 V consumption of the CI854BK01?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified typical 24 V consumption is 190 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the CI854BK01 assembly on a suitable DIN rail using the TP854 baseplate.\u003c\/li\u003e\n\u003cli\u003eConnect the interface to the AC 800M CEX Bus according to the applicable system architecture.\u003c\/li\u003e\n\u003cli\u003eConnect PROFIBUS cables to the designated 9-pin female DB connectors.\u003c\/li\u003e\n\u003cli\u003eMaintain PROFIBUS termination at the two outermost network nodes.\u003c\/li\u003e\n\u003cli\u003eWhen using connector-integrated termination, keep the terminating connector plugged in and powered.\u003c\/li\u003e\n\u003cli\u003eSeparate PROFIBUS communication wiring from high-current and high-noise power conductors where practical.\u003c\/li\u003e\n\u003cli\u003eFollow the applicable PROFIBUS cable shielding and grounding requirements for the installation.\u003c\/li\u003e\n\u003cli\u003eVerify the network topology and redundancy configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm software compatibility with System 800xA 6.0.3.2 or later and Compact Control Builder 6.0.0-2 or later.\u003c\/li\u003e\n\u003cli\u003eObserve the specified 0 to +55 deg C operating temperature range during installation and operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623619424344,"sku":"CI854BK01 CI854B+TP854","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI854BK01-CI854B-TP854-3_1200x1200_507a229a-4d5e-47fe-bb43-6010b7792ef2.jpg?v=1787129024","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ci854bk01-ci854b-tp854-abb-profibus-dp-communication-interface","provider":"IndustriaX Limited","version":"1.0","type":"link"}