{"product_id":"cc-paih02-51405038-175-c300-hart-analog-input-module-honeywell","title":"CC-PAIH02 51405038-175 | C300 HART Analog Input Module | Honeywell","description":"\u003ch2\u003eHoneywell CC-PAIH02 C300 HART Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for HART analog signal acquisition in Honeywell Experion PKS C300 control system platforms, the \u003cstrong\u003eHoneywell CC-PAIH02\u003c\/strong\u003e (\u003cstrong\u003eCC-PAIH02\u003c\/strong\u003e HART Analog Input Module) provides direct physical and electrical execution for differential and single-ended field input processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-PAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHART Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS C300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDifferential \/ Single-ended Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Input Signals\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 V, 0-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eHART loop protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHART Loop Protocol and Channel Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe CC-PAIH02 is designed for process instrumentation signal acquisition using HART-enabled field devices. The module supports 16 analog input channels with current and voltage measurement capability, including 4-20 mA current loops and standard voltage inputs.\u003c\/p\u003e\n\u003cp\u003eThe HART interface allows digital communication data to be exchanged over the analog signal loop, enabling access to transmitter parameters and diagnostic information when connected to compatible field instruments.\u003c\/p\u003e\n\u003cp\u003eChannel-to-channel isolation and signal conditioning functions are implemented within the I\/O architecture to maintain electrical separation between field wiring and controller processing circuits. Proper shield termination and grounding practices are required to minimize electromagnetic interference during analog signal transmission.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signals are supported by the Honeywell CC-PAIH02?\u003cbr\u003eA: The CC-PAIH02 supports differential and single-ended analog inputs including 4-20 mA, 1-5 V, and 0-5 V signal types.\u003c\/p\u003e\n\u003cp\u003eQ: How many field input channels are available on the CC-PAIH02?\u003cbr\u003eA: The module provides 16 analog input channels for connection to compatible field transmitters and instrumentation devices.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CC-PAIH02 support HART communication?\u003cbr\u003eA: Yes. The module supports HART loop protocol communication for compatible HART-enabled analog field devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module within the designated Honeywell Experion PKS C300 I\/O hardware assembly according to system engineering documentation.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring polarity before applying power to prevent incorrect signal acquisition.\u003c\/li\u003e\n\u003cli\u003eUse shielded instrumentation cables for analog input wiring where required by site electrical standards.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields using approved grounding methods to reduce electrical noise and signal interference.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level analog signal cables from high-voltage power wiring and switching circuits.\u003c\/li\u003e\n\u003cli\u003eConfirm that connected transmitters match the supported input ranges before commissioning.\u003c\/li\u003e\n\u003cli\u003eCheck controller configuration parameters to ensure channel assignments correspond with the physical field wiring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44341123448920,"sku":"CC-PAIH02 51405038-175","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-PAIH0251405038-175-3.jpg?v=1783413249","url":"https:\/\/www.industriaxplc.com\/ar\/products\/cc-paih02-51405038-175-c300-hart-analog-input-module-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}