{"product_id":"cc-mcarw1-gi-is-carrier-channel-assembly-honeywell","title":"CC-MCARW1 | GI\/IS Carrier Channel Assembly | Honeywell","description":"\u003ch2\u003eHoneywell CC-MCARW1 GI\/IS Carrier Channel Assembly\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-MCARW1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCC-MCARW1\u003c\/strong\u003e GI\/IS Carrier Channel Assembly, operates as a dedicated hardware component for signal routing and channel interface execution within Honeywell Experion PKS Series-C I\/O subsystems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-MCARW1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eGI\/IS Carrier Channel Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Experion PKS Series-C I\/O Subsystems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Role\u003c\/td\u003e\n\u003ctd\u003eCarrier channel assembly for I\/O signal and power interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDC powered carrier assembly; value depends on installed configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated Ethernet capability \/ fault transparency support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eG3 conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 40.5 cm x 14.5 cm x 3.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.0 kg net weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eCSA Class I Division 2, IECEx Zone 2, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CC-MCARW1 is applied within Honeywell process control I\/O architectures where field signal interfaces require controlled routing between field termination assemblies and controller-side modules. Honeywell Series-C I\/O designs support process instrumentation interfaces including 4-20 mA HART loop protocol handling through compatible I\/O modules. Channel-to-channel isolation depends on the associated I\/O module and termination configuration installed with the carrier assembly.\u003c\/p\u003e\n\u003cp\u003eThe G3 conformal coating provides protection of electronic assemblies against industrial contaminants including moisture, dust, and corrosive atmospheric exposure. The carrier assembly maintains electrical separation requirements for GI\/IS applications when installed according to the approved system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CC-MCARW1 a standalone controller module?\u003cbr\u003eA: No. The CC-MCARW1 is a carrier channel assembly used as part of the Honeywell Experion PKS Series-C I\/O subsystem architecture. It provides physical mounting and interface functions for compatible I\/O configurations.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CC-MCARW1 support hazardous area applications?\u003cbr\u003eA: Yes. The assembly is specified for hazardous location environments including CSA Class I Division 2, IECEx Zone 2, and ATEX Zone 2 applications when installed within the approved system design.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CC-MCARW1 operate without a connected I\/O module assembly?\u003cbr\u003eA: The carrier assembly is designed for use with compatible Honeywell I\/O system components. Operation depends on the installed module configuration and system wiring arrangement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the CC-MCARW1 according to Honeywell Experion PKS Series-C hardware installation documentation.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility between the carrier assembly, connected I\/O modules, and termination components before energization.\u003c\/li\u003e\n\u003cli\u003eMaintain proper field wiring separation between signal circuits, power conductors, and hazardous area interfaces.\u003c\/li\u003e\n\u003cli\u003eUse approved grounding and shielding practices for instrument signal cables to minimize electrical interference.\u003c\/li\u003e\n\u003cli\u003eInspect connector interfaces and mounting points for contamination, mechanical damage, or improper seating before system startup.\u003c\/li\u003e\n\u003cli\u003eConfirm environmental conditions remain within the specified operating temperature and humidity limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44341014167640,"sku":"CC-MCARW1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-MCARW1-3.jpg?v=1783408421","url":"https:\/\/www.industriaxplc.com\/ar\/products\/cc-mcarw1-gi-is-carrier-channel-assembly-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}