{"product_id":"cc-gaix21-honeywell-analog-input-gi-is-iota","title":"CC-GAIX21 | Honeywell | Analog Input GI\/IS IOTA","description":"\u003ch2\u003eHoneywell CC-GAOX21 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog current signal output in Honeywell distributed control system (DCS) architectures, the \u003cstrong\u003eHoneywell CC-GAOX21\u003c\/strong\u003e (\u003cstrong\u003eCC-GAOX21\u003c\/strong\u003e Analog Output Module) provides direct electrical execution. The module delivers 16 independent analog output channels with configurable 4-20 mA current signals and output readback capability for closed-loop process control.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single catalog number: \u003cstrong\u003eCC-GAOX21\u003c\/strong\u003e. No official suffix variants or model matrix information are provided. No suffix interpretation is included.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-GAOX21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 cm x 18.8 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ripple\u003c\/td\u003e\n\u003ctd\u003eLess than 100 mV peak-to-peak at power line frequency across 250 Ohm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Temperature Drift\u003c\/td\u003e\n\u003ctd\u003e0.005 % of full scale\/deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Readback Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 4 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05 % of full scale nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.35 % of full scale at 25 deg C including linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDirectly Settable Output Current Range\u003c\/td\u003e\n\u003ctd\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Output Compliance Voltage\u003c\/td\u003e\n\u003ctd\u003e16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Considerations\u003c\/h3\u003e\n\u003cp\u003eThe CC-GAOX21 is intended for multi-channel analog current transmission in process automation applications. Proper channel isolation within the control cabinet minimizes coupling between adjacent output circuits, reducing measurement interference when multiple 4-20 mA loops operate simultaneously. Installation practices should maintain separation between analog output wiring and high-energy power conductors, while shield termination should follow the applicable DCS cabinet grounding standard to reduce conducted and radiated electrical noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support hot replacement while the controller remains energized?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied documentation does not specify hot-swap capability. Replacement procedures should follow the applicable Honeywell system maintenance documentation and plant operating procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can each channel be configured for output values outside the standard 4-20 mA range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The documented directly settable output current range is 0 mA and 2.9 mA to 21.1 mA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the module power consumption specified?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The provided technical data does not include module power consumption or backplane current requirements.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify module catalog number before installation into the designated I\/O carrier or chassis.\u003c\/li\u003e\n\u003cli\u003eIsolate system power before inserting or removing the module unless the host platform documentation explicitly permits energized replacement.\u003c\/li\u003e\n\u003cli\u003eRoute analog output wiring separately from AC power and motor cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the control cabinet grounding practice specified for the installation.\u003c\/li\u003e\n\u003cli\u003eConfirm load impedance remains within the allowable operating conditions of the analog output circuit.\u003c\/li\u003e\n\u003cli\u003ePerform output verification and loop calibration after installation using the system engineering tools and field instrumentation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44318455562328,"sku":"CC-GAOX21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-GAOX21-3.jpg?v=1783061574","url":"https:\/\/www.industriaxplc.com\/ar\/products\/cc-gaix21-honeywell-analog-input-gi-is-iota","provider":"IndustriaX Limited","version":"1.0","type":"link"}