{"product_id":"cc-gaix21-51306309-175-analog-input-module-honeywell","title":"CC-GAIX21 51306309-175 | Analog Input Module | Honeywell","description":"\u003ch2\u003eHoneywell CC-GAIX21 51306309-175 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for analog signal acquisition in a Honeywell process control system, the \u003cstrong\u003eHoneywell CC-GAIX21 51306309-175\u003c\/strong\u003e (\u003cstrong\u003eCC-GAIX21\u003c\/strong\u003e Analog Input Module) provides direct electrical conversion of field voltage signals into digital process data. The module incorporates a 16-bit A\/D converter with defined common-mode and normal-mode rejection characteristics for analog measurement channels.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe supplied documentation identifies a single catalog number: \u003cstrong\u003eCC-GAIX21 51306309-175\u003c\/strong\u003e. No official suffix or option code breakdown is provided; therefore, no model matrix or suffix interpretation is included.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-GAIX21 51306309-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 cm x 18.8 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e70 dB, dc to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e-6 V to +5 V peak, dc to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection Ratio\u003c\/td\u003e\n\u003ctd\u003e19 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Filter\u003c\/td\u003e\n\u003ctd\u003eSingle-pole RC, -3 dB at 6.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Normal Mode Input\u003c\/td\u003e\n\u003ctd\u003e+\/- 30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCrosstalk\u003c\/td\u003e\n\u003ctd\u003e-60 dB, dc to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance (Voltage Inputs)\u003c\/td\u003e\n\u003ctd\u003eGreater than 10 MOhm, powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Scan Rate\u003c\/td\u003e\n\u003ctd\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe module is intended for analog signal acquisition within distributed process control architectures. Proper channel separation depends on cabinet wiring practice, shield termination, and field cable routing. When multiple analog channels are installed in the same enclosure, segregating analog wiring from high-energy power conductors helps maintain the specified common-mode rejection, normal-mode rejection, and crosstalk performance. Where applicable, channel-to-channel isolation provided by the system architecture should be preserved by following the platform wiring requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support hot replacement while the controller is operating?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied documentation does not specify hot-swap capability. Module replacement should follow the maintenance procedure defined for the installed Honeywell control platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the operating temperature range specified?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The provided technical information does not include environmental operating limits. Refer to the official platform documentation for installation environment requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module accept higher transient input voltages than the specified analog range?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The documented maximum normal-mode input is +\/- 30 V. Input wiring should be designed so normal operating and transient conditions remain within the published electrical limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify module catalog number before installation to ensure compatibility with the target Honeywell I\/O carrier or chassis.\u003c\/li\u003e\n\u003cli\u003eRemove or isolate system power in accordance with plant maintenance procedures unless the installed platform explicitly supports online replacement.\u003c\/li\u003e\n\u003cli\u003eRoute analog input cables separately from AC power, motor, and relay wiring to reduce induced electrical noise.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the system grounding specification to minimize ground loops.\u003c\/li\u003e\n\u003cli\u003eTighten field wiring terminals using the torque specified by the terminal hardware documentation.\u003c\/li\u003e\n\u003cli\u003eInspect connector engagement and module seating after installation before restoring system operation.\u003c\/li\u003e\n\u003cli\u003ePerform channel verification and input signal validation after commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44301231980632,"sku":"CC-GAIX21","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CC-GAIX21-3.jpg?v=1782891237","url":"https:\/\/www.industriaxplc.com\/ar\/products\/cc-gaix21-51306309-175-analog-input-module-honeywell","provider":"IndustriaX Limited","version":"1.0","type":"link"}