{"product_id":"bmxsai0410-safety-analog-input-module-schneider-electric","title":"BMXSAI0410 Safety Analog Input Module | Schneider Electric","description":"\u003ch2\u003eSchneider Electric BMXSAI0410 Safety Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-integrity signal acquisition in Safety Instrumented Systems (SIS), the \u003cstrong\u003eSchneider Electric BMXSAI0410\u003c\/strong\u003e (\u003cstrong\u003eBMXSAI\u003c\/strong\u003e Safety Analog Input Module) provides direct physical\/electrical execution of 4-20 mA current loops into deterministic digital data via the X80 backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric BMXSAI0410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e340 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.8 cm x 17.9 cm x 5.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W typical (via backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Number\u003c\/td\u003e\n\u003ctd\u003e4 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent 4...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Resolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Resolution\u003c\/td\u003e\n\u003ctd\u003e2 uA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V DC (Channel-Ch) \/ 1500 V DC (Ch-GND\/Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Read Cycle\u003c\/td\u003e\n\u003ctd\u003e6 ms for 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Architecture and Fail-Safe Execution\u003c\/h3\u003e\n\u003cp\u003eThe module supports integration into SIL3-rated architectures utilizing triple modular redundancy principles. It executes fail-safe state transitions upon detection of open-circuit or over-range conditions exceeding 25 mA. Channel-to-channel galvanic isolation is maintained at 500 V DC to prevent ground loop interference and ensure data integrity during partial system faults.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the BMXSAI0410 support hot-swap removal under load?\u003c\/p\u003e\n\u003cp\u003eA: No. The module must be de-energized prior to removal or insertion to prevent arcing on the 20-way connector and to maintain the integrity of the safety checksum.\u003c\/p\u003e\n\u003cp\u003eQ: What is the default scaling for the raw digital value?\u003c\/p\u003e\n\u003cp\u003eA: The default user scale is +\/- 10000 counts. Recalibration and scaling to +\/- 32000 counts must be configured via the control system programming software.\u003c\/p\u003e\n\u003cp\u003eQ: How is crosstalk suppressed between adjacent channels?\u003c\/p\u003e\n\u003cp\u003eA: Crosstalk attenuation is maintained at a minimum of 120 dB through independent conversion resistors and second-order digital filtering per channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module onto a standard 35 mm DIN rail within the X80 rack. Ensure the shield of the analog input cables is terminated at the cable gland or terminal block to maintain EMC compliance. Torque the connector screws to 0.5 Nm. Verify the gap voltage and loop continuity before applying power to the safety controller.\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":44273285562456,"sku":"BMXSAI0410","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/BMXSAI0410-3.jpg?v=1782290676","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bmxsai0410-safety-analog-input-module-schneider-electric","provider":"IndustriaX Limited","version":"1.0","type":"link"}