{"product_id":"bently-nevada102566-02-rtd-input-module","title":"Bently Nevada102566-02 RTD Input Module","description":"\u003ch2\u003eBently Nevada102566-02 RTD Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eUnknown 102566-02\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e102566-02 RTD Input Module\u003c\/strong\u003e, operates as a dedicated hardware component for resistance temperature detector signal acquisition within distributed control and process monitoring architectures. The unit processes 8 independent RTD channels supporting Pt100, Pt500, and Pt1000 sensing elements, converting resistance variation into digital temperature data with 0.1 deg C resolution and HART-enabled communication output.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo formally documented suffix segmentation or hierarchical ordering is available for model 102566-02 based on the provided dataset. The identifier is treated as a single fixed-order part number without exposed functional suffix encoding.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e102566-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRTD Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 RTD Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt500, Pt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e-200 deg C to +850 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.1 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDigital communication with HART protocol support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 mm x 16.2 mm x 10.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRTD Signal Conditioning and HART Loop Integration\u003c\/h3\u003e\n\u003cp\u003eThe module implements multi-channel RTD resistance acquisition with linearization processing for Pt-based sensor curves. Each channel performs excitation current regulation and resistance-to-temperature conversion prior to digital domain encoding. The HART protocol layer is used for cyclic and acyclic data exchange, enabling remote configuration of sensor type selection, measurement scaling, and diagnostic readback over the same field wiring infrastructure.\u003c\/p\u003e\n\u003cp\u003eChannel sampling is executed in parallelized input scanning, reducing inter-channel temporal skew during multi-point thermal mapping applications. Input impedance balancing is applied to minimize lead-wire induced measurement deviation in 2-wire, 3-wire, and 4-wire RTD configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support mixed RTD types across channels simultaneously?\u003cbr\u003eA: The hardware supports Pt100, Pt500, and Pt1000 sensing elements per channel configuration. Mixed operation is determined by channel-level configuration rather than global module locking.\u003c\/p\u003e\n\u003cp\u003eQ: What is the impact of channel loading on power consumption?\u003cbr\u003eA: Total power consumption remains approximately 5 W under full channel utilization. Internal excitation circuits distribute load across independent measurement paths.\u003c\/p\u003e\n\u003cp\u003eQ: Is HART communication isolated per channel?\u003cbr\u003eA: HART signaling is implemented at the module communication layer rather than per-channel physical isolation; channel separation is maintained electrically within the input conditioning stage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be mounted on a DIN rail or equivalent industrial mounting structure with attention to mechanical alignment tolerance to prevent connector stress. RTD input wiring shall use shielded twisted pair conductors, with shield termination performed at a single grounding point to avoid ground loop formation.\u003c\/p\u003e\n\u003cp\u003eFor 3-wire and 4-wire RTD configurations, ensure symmetrical lead resistance and consistent conductor length across measurement pairs. Power supply wiring must be separated from signal cabling to minimize inductive coupling. Installation environment shall remain within specified operating temperature limits of -40 deg C to +85 deg C, with adequate ventilation to maintain thermal stability of the electronics assembly.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44306879676504,"sku":"102566-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/102566-02-3.jpg?v=1782984255","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada102566-02-rtd-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}