{"product_id":"bently-nevada-3500-65-172115-01-external-connection-terminal-block","title":"Bently Nevada 3500\/65 172115-01 External connection Terminal Block","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eBently Nevada\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an external termination I\/O assembly engineered for use with the Bently Nevada 3500\/65 Temperature Monitor. The module serves as the field wiring interface for RTD and thermocouple sensors in machinery protection systems requiring accessible and organized external connections.\u003c\/p\u003e\n\u003cp\u003eUnlike internally terminated configurations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows sensor wiring to terminate on a dedicated external terminal strip, simplifying installation, troubleshooting, and maintenance activities within industrial control cabinets.\u003c\/p\u003e\n\u003cp\u003eThe module is designed for high-reliability temperature monitoring applications commonly found in turbines, compressors, generators, and rotating equipment protection systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides a structured interface between field-mounted temperature sensors and the 3500 rack monitoring system.\u003c\/p\u003e\n\u003cp\u003ePrimary operational functions include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExternal termination for RTD and thermocouple inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure screw-terminal field wiring connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupport for multiple RTD wiring configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCold junction compensation support for thermocouples\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielded signal routing for improved EMI resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane communication with the 3500\/65 monitor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimplified field maintenance without monitor removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe external wiring layout improves accessibility in large or high-density control panels.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module supports common industrial temperature sensing technologies used in critical machinery protection environments.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported RTD Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eRTD Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eWiring Method\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePt100 Platinum\u003c\/td\u003e\n\u003ctd\u003e2-wire \/ 3-wire \/ 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNi120 Nickel\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCu10 Copper\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003eSupported Thermocouple Inputs\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eThermocouple Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eIndustrial Application\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType J\u003c\/td\u003e\n\u003ctd\u003eGeneral process temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType K\u003c\/td\u003e\n\u003ctd\u003eHigh-temperature equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType E\u003c\/td\u003e\n\u003ctd\u003ePrecision thermal monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType T\u003c\/td\u003e\n\u003ctd\u003eLow-temperature applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIntegrated cold-junction compensation improves thermocouple measurement stability and accuracy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExternal Termination I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Monitor\u003c\/td\u003e\n\u003ctd\u003e3500\/65 Temperature Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003e3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Style\u003c\/td\u003e\n\u003ctd\u003eExternal Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e6 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Sensors\u003c\/td\u003e\n\u003ctd\u003eRTD and Thermocouple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Support\u003c\/td\u003e\n\u003ctd\u003ePt100, Ni120, Cu10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eJ, K, E, T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003eScrew-terminal connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Routing\u003c\/td\u003e\n\u003ctd\u003eShielded industrial design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel and ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eExternal rack terminal strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Rating\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade rugged housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe module is optimized for electrically noisy environments where stable low-level temperature signal transmission is required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexternal termination arrangement offers practical advantages for industrial maintenance and cabinet integration.\u003c\/p\u003e\n\u003cp\u003eTypical benefits include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEasier sensor replacement and rewiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduced maintenance downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCleaner cable organization inside control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproved accessibility for commissioning technicians\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimplified troubleshooting procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBetter suitability for remote or distributed field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese characteristics make the module especially useful in large turbine control cabinets and high-channel-count monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Industrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly installed in temperature monitoring systems protecting critical rotating equipment.\u003c\/p\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine bearing temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor thermal supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator winding protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump bearing temperature measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox housing temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLubrication oil temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeal oil system temperature monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is frequently selected where external wiring accessibility is a project requirement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eComparison with Related 3500\/65 I\/O Modules\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003ePart Number\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTermination Type\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eApplication Style\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e172103-01\u003c\/td\u003e\n\u003ctd\u003eInternal Termination\u003c\/td\u003e\n\u003ctd\u003eCompact cabinet installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e172115-01\u003c\/td\u003e\n\u003ctd\u003eExternal Termination\u003c\/td\u003e\n\u003ctd\u003eAccessible field wiring systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e172115-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis preferred when maintenance access and organized field termination are priorities.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary purpose of the 172115-01 module?\u003c\/strong\u003e\u003cbr\u003eThe module provides external field termination for RTD and thermocouple wiring connected to the 3500\/65 Temperature Monitor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module support both RTD and thermocouple sensors?\u003c\/strong\u003e\u003cbr\u003eYes. It supports Pt100, Ni120, Cu10 RTDs and J, K, E, T thermocouples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can wiring be serviced without removing the monitor module?\u003c\/strong\u003e\u003cbr\u003eYes. External termination allows field wiring maintenance independently from the monitor card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 172115-01 compatible with all 3500 systems?\u003c\/strong\u003e\u003cbr\u003eIt is specifically designed for use with the Bently Nevada 3500\/65 Temperature Monitor configuration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44125922230360,"sku":"3500\/65 172115-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/350065172115-012.jpg?v=1779356605","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-3500-65-172115-01-external-connection-terminal-block","provider":"IndustriaX Limited","version":"1.0","type":"link"}