{"product_id":"bently-nevada-3500-62-133811-03-process-variable-monitor","title":"Bently Nevada 3500\/62 133811-03 Process Variable Monitor","description":"\u003ch2\u003eBently Nevada 3500\/62 133811-03 Process Variable Monitor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/62 133811-03\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e133811-03\u003c\/strong\u003e Process Variable Monitor, operates as a dedicated hardware component for process signal measurement within the Bently Nevada 3500 Monitoring System. It accepts voltage and current input signals and processes analog process variables for machinery protection applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/62 133811-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProcess Variable Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 x 29 x 23 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, noncondensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e+\/-10 VDC I\/O, -10 VDC to +10 VDC; 4-20 mA Barrier I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Compliance\u003c\/td\u003e\n\u003ctd\u003e13.66 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.0 Watts typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eWithin +\/-0.33% of full scale typical, +\/-1% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Platform\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Processing and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3500\/62 133811-03 Process Variable Monitor processes analog signals through defined input ranges for integration with the 3500 rack architecture. The module supports voltage and current input measurement, including +\/-10 VDC signals and 4-20 mA barrier inputs.\u003c\/p\u003e\n\u003cp\u003eFor applications involving eddy-current measurement systems, signal scaling and gap voltage validation methods are applied to maintain correct transducer measurement conditions. The module supports monitoring configurations where rotor displacement and machine process variables require consistent electrical signal conversion.\u003c\/p\u003e\n\u003cp\u003eMoreover, the module architecture provides 500 Volt isolation between signal circuits, reducing interference from external electrical sources. This isolation supports stable data acquisition in machinery monitoring environments where signal integrity is required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal types does the 3500\/62 133811-03 support?\u003cbr\u003eA: The module supports +\/-10 VDC analog inputs and 4-20 mA DC barrier inputs for process variable monitoring applications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the typical power consumption of this Process Variable Monitor?\u003cbr\u003eA: The module consumes approximately 7.0 Watts under typical operating conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module provide electrical isolation?\u003cbr\u003eA: Yes. The 3500\/62 133811-03 provides 500 Volt isolation for signal circuit separation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in a compatible Bently Nevada 3500 rack configuration.\u003c\/li\u003e\n\u003cli\u003eVerify rack power availability before module insertion or removal.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the specified voltage and current input requirements.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded signal cables for analog measurement circuits.\u003c\/li\u003e\n\u003cli\u003eGround cable shields according to site electrical grounding practices to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eSeparate low-level analog signal wiring from high-voltage power cables during installation.\u003c\/li\u003e\n\u003cli\u003eConfirm input polarity and signal range configuration before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44356764074072,"sku":"133811-03","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/133811-03-3.jpg?v=1783664356","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-3500-62-133811-03-process-variable-monitor","provider":"IndustriaX Limited","version":"1.0","type":"link"}