{"product_id":"bently-nevada-3500-22m-transient-data-interface-module","title":"Bently Nevada 3500\/22M Transient Data Interface Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 3500\/22M Transient Data Interface Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eConfigured for real-time and transient data acquisition in the 3500 Machinery Protection System, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eBently Nevada\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e3500\/22M (288055-02)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3500\/22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransient Data Interface Module) provides direct physical\/electrical execution between rack-level monitoring hardware and host diagnostic software interfaces. It operates as a communication and data buffering node within the 3500 rack architecture, supporting waveform capture and event data transfer via Ethernet and serial channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/22M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX Ethernet, 100Base-FX Fiber Optic, USB-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Handling\u003c\/td\u003e\n\u003ctd\u003eReal-time monitoring, transient waveform capture, event logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffer Memory\u003c\/td\u003e\n\u003ctd\u003eIntegrated transient data storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd\u003eOK Relay, 5 A @ 24 VDC \/ 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Position\u003c\/td\u003e\n\u003ctd\u003eSlot 1 (adjacent to power supply modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI Data Interface Architecture and Signal Buffering Behavior\u003c\/h3\u003e\n\u003cp\u003eThe module functions as a non-critical path interface element within the TSI monitoring chain of the 3500 system. It does not participate in protective trip logic execution but maintains continuous data acquisition from rack monitors.\u003c\/p\u003e\n\u003cp\u003eFrom a rotor dynamics perspective, the module supports indirect analysis workflows involving eddy-current probe scaling and gap voltage validation (typically referenced against -10 VDC sensor range calibration structures). It performs waveform buffering prior to transmission to host software, reducing communication jitter during high-frequency vibration sampling events.\u003c\/p\u003e\n\u003cp\u003eCross-channel synchronization is maintained through rack-level addressing logic (up to 127 node addresses), with internal buffering isolating transient bursts from Ethernet throughput constraints. This architecture minimizes cross-talk propagation effects between parallel monitoring channels in high-density rack configurations.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo validated suffix decomposition beyond order number differentiation is defined in the provided dataset.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e3500\/22M: Transient Data Interface Module designation within 3500 system family\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e288055-02: Order-specific configuration identifier\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3500\/22M participate in machinery protection trip logic execution?\u003cbr\u003eA: No. The module operates outside the protective loop and functions as a communication and data interface layer only.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module buffer transient waveform data during Ethernet link interruption?\u003cbr\u003eA: Yes. Integrated buffer memory stores transient and event data temporarily until communication link restoration.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if the TDI module is removed from the 3500 rack?\u003cbr\u003eA: Rack-based protection monitoring continues through M-series modules; only host communication and data acquisition functions are affected.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall in Slot 1 of the 3500 rack adjacent to power supply modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure backplane connectors are fully seated to maintain communication integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shielded Ethernet\/fiber routing to reduce EMI coupling in turbine environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse keyed configuration switch to define RUN or PROGRAM mode prior to system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify rack address assignment (1–127 range) before host software initialization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44295397179480,"sku":"288055-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/288055-01.jpg?v=1782805181","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-3500-22m-transient-data-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}