{"product_id":"bently-nevada-3300-16-15-01-03-00-00-02-vibration-monitor-module","title":"Bently Nevada 3300\/16-15-01-03-00-00-02 Vibration Monitor Module","description":"\u003ch1\u003eBently Nevada 3300\/16 Vibration Monitor Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for dual-channel radial vibration and shaft gap electrical conversion in 3300 rack based proximity transducer networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16-15-01-03-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3300\/16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eXY\/GAP Dual Vibration Monitor) provides direct physical\/electrical execution of eddy-current probe signal conditioning and alarm logic processing across Bently Nevada 3300 monitoring platforms.\u003c\/p\u003e\n\u003cp\u003eThe module processes two independent proximity probe inputs with fixed sensitivity scaling (200 mV\/mil) and converts shaft displacement into conditioned peak-to-peak vibration and DC gap voltage signals. Internal alarm logic supports relay output configuration (quad relay epoxy sealed type) for threshold-based trip and warning states.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3300\/16\u003c\/strong\u003e: XY\/GAP dual-channel vibration monitor base module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-15\u003c\/strong\u003e: Full-scale range option, 0 to 500 um peak-to-peak equivalent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-01\u003c\/strong\u003e: Proximitor input compatibility (3300 \/ 3300 XL \/ 7200 systems, 200 mV\/mil)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-03\u003c\/strong\u003e: Quad relay alarm output configuration (epoxy sealed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: Agency approval not required configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: No intrinsic safety barriers installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-00\u003c\/strong\u003e: No trip multiply function enabled\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300\/16-15-01-03-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1kg (shipping weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e3300 \/ 7200 Proximitor, 200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eDual (X-Y radial vibration + gap)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 um peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003eQuad relay (epoxy sealed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation Behavior\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/16 platform applies fixed eddy-current probe scaling using calibrated 200 mV\/mil sensitivity conversion to translate probe air-gap variation into electrical displacement signals. Gap voltage validation is referenced against stable DC operating points derived from proximity probe bias conditions, enabling continuous monitoring of shaft centerline position drift. Cross-channel interaction suppression is implemented at analog conditioning stage to reduce coupling between X and Y measurement paths during high amplitude rotor orbit conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the quad relay output be used for independent alarm zoning?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the quad relay configuration supports discrete alarm assignment per channel or combined logic outputs depending on backplane configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module require software configuration for scaling?\u003c\/strong\u003e\u003cbr\u003eA: Scaling is hardware-defined via factory option (-15), no field programmable scaling is applied to the measurement chain.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is channel synchronization required for X-Y vibration measurement?\u003c\/strong\u003e\u003cbr\u003eA: Channels operate in parallel analog paths; phase relationship is preserved inherently without digital synchronization logic.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall module only into compatible 3300 rack slot with secure backplane engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify proximity probe wiring polarity and shielding continuity before energization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse single-point grounding for coaxial and probe cable shields to avoid ground loop currents\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain separation between signal cabling and high voltage conductors to reduce induced noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure relay output wiring matches intended alarm logic configuration prior to system start-up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44241943986264,"sku":"3300\/16-15-01-03-00-00-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330016-15-01-03-00-00-02-3_e4e54a9f-1b24-4f46-af8f-1b100cb1b3d2.jpg?v=1781507175","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-3300-16-15-01-03-00-00-02-vibration-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}