{"product_id":"bently-nevada-3300-01-01-00-system-monitor-module","title":"Bently Nevada 3300\/01-01-00 System Monitor Module","description":"\u003ch1\u003eBently Nevada 3300\/01-01-00 System Monitor Module\u003c\/h1\u003e\n\u003cp\u003eConfigured for centralized rack coordination and signal distribution in the Bently Nevada 3300 Machinery Protection System, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3300\/01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem Monitor Module) provides direct physical and electrical execution of monitoring, alarm management, and transducer interfacing tasks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eSuffix\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eDefinition\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e3300\/01\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eSystem Monitor Module base model\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-01\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard agency approvals (CSA\/NRTL\/C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e-00\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eNo modification \/ standard interface option\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\n\u003cp\u003eParameter\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eSpecification\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eModel Brand\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eBently Nevada\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOrigin\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eUnited States\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.55 kg\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimensions\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard 3300 rack slot width\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOperating Temp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 degC to +65 degC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStorage Temp\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-40 degC to +85 degC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eRelative Humidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e95% non-condensing\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003ePower Consumption\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-24 VDC via backplane\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eOutput Impedance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e100 ohm buffered Keyphasor outputs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/01-01-00 supports precise eddy-current probe scaling through linearized target calibration against API 670 requirements. Gap voltage validation targets a nominal -10 VDC bias under static conditions, ensuring transducer health prior to rotor dynamics measurement. Signal crosstalk suppression is maintained between channels via isolated return paths and screened cabling practices within the rack assembly.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3300\/01-01-00 support hot-swap replacement without rack power-down?\u003c\/p\u003e\n\u003cp\u003eA: No. Backplane power must be removed before removal or insertion to prevent damage to connectors and maintain signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: What is the alarm inhibit duration during power-up?\u003c\/p\u003e\n\u003cp\u003eA: The internal Power-up Inhibit function suppresses alarm outputs for approximately 2 seconds after supply stabilization.\u003c\/p\u003e\n\u003cp\u003eQ: Can the buffered Keyphasor outputs drive multiple diagnostic devices simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided total load impedance does not fall below 10 kohm per output to avoid signal attenuation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module into the designated leftmost slot of the 3300 rack to ensure correct backplane addressing. Use shielded twisted-pair cable for all transducer wiring, terminating shields at the rack ground busbar. Verify gap voltage at each proximity probe before final rack commissioning. Ensure all dry-contact inhibit wiring uses adequately rated control cables segregated from high-voltage conductors. Maintain minimum clearance around ventilation slots to prevent thermal accumulation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44247956291672,"sku":"3300\/01-01-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330001-01-00-3.jpg?v=1781659136","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-3300-01-01-00-system-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}