{"product_id":"bently-nevada-24583-04-3300-xl-proximitor-sensor","title":"Bently Nevada 24583-04 3300 XL Proximitor Sensor","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 24583-04 3300 XL Proximitor Sensor\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eConfigured for conversion of eddy-current proximity probe signals into calibrated displacement and vibration outputs in 3300 XL monitoring architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 24583-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e24583-04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximitor Sensor) provides direct electrical signal conditioning and scaling for shaft position measurement within the 3300 XL instrumentation chain.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 24583-04 is a single defined orderable sensor identifier within the 3300 XL Proximitor Sensor family. No validated functional segmentation or suffix-based hardware partition is specified in the provided dataset. System behavior is determined by probe type selection and external monitoring configuration parameters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e24583-04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 76 x 25 x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e2 mm to 80 mm (probe dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e0.25 mm to 2.0 mm typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.25 percent of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput\u003c\/td\u003e\n\u003ctd\u003e3300 XL proximity probe compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e-200 mV\/mil (7.87 mV\/um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e-24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance\u003c\/td\u003e\n\u003ctd\u003eAPI 670, CE, UL, CSA, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBently Nevada Eddy-Current Probe Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 24583-04 implements eddy-current signal linearization for shaft displacement conversion based on calibrated probe gap-voltage response characteristics. Output scaling is referenced to standardized -200 mV\/mil conversion factors used in the 3300 XL system architecture. Cross-talk suppression is implemented through internal shielding geometry and differential reference handling to reduce channel interaction in multi-probe installations. Signal integrity is maintained across DC to 10 kHz bandwidth for both static position and dynamic vibration extraction.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 24583-04 operate with non-3300 XL proximity probes?\u003cbr\u003eA: No. The input conditioning network is calibrated for 3300 XL probe electrical characteristics. Non-matching probe impedance results in non-linear displacement scaling.\u003c\/p\u003e\n\u003cp\u003eQ: Does the sensor require external signal conditioning modules?\u003cbr\u003eA: No external conditioning is required. The device provides direct proportional voltage output suitable for monitoring system input channels.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if the -24 VDC supply deviates from nominal range?\u003cbr\u003eA: Output scaling integrity is maintained only within specified supply tolerance. Deviation outside design range may introduce linearity drift or reduced measurement stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the sensor in a grounded metallic enclosure to maintain shielding integrity of eddy-current measurement circuits. Keep probe signal wiring separated from high-voltage or switching conductors to reduce electromagnetic coupling. Use twisted shielded cable with single-point grounding at the monitoring system end. Avoid sharp bends in probe extension cables to maintain impedance stability. Verify correct polarity and stability of the -24 VDC supply prior to energization of the measurement loop.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44291618013272,"sku":"24583-04","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/24583-04.jpg?v=1782729986","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-24583-04-3300-xl-proximitor-sensor","provider":"IndustriaX Limited","version":"1.0","type":"link"}