{"product_id":"bently-nevada-200200-03-03-05-temperature-interface-modules","title":"Bently Nevada 200200-03-03-05 Temperature Interface Modules","description":"\u003ch2\u003eBently Nevada 200200-03-03-05 Trendmaster proTIM-R Temperature Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 200200-03-03-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e200200\u003c\/strong\u003e proTIM-R Temperature Interface Module, operates as a dedicated hardware component for dual-channel RTD temperature signal acquisition within the Trendmaster distributed condition monitoring system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e200200-03-03-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eTrendmaster 200 Series proTIM-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProcessor Transducer Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.77 lbs (349 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 11.6 cm x 2.5 cm x 2.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e2 independent temperature input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Input Type\u003c\/td\u003e\n\u003ctd\u003e2-wire or 3-wire Platinum RTD (Pt100 typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eAnalog signal conditioning and digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003eIsolated temperature input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eTrendmaster data highway communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Temperature Signal Processing and Mechanical Monitoring Features\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 200200-03-03-05 processes RTD temperature signals through dedicated input conditioning circuits before transferring measurement data to the Trendmaster monitoring network. Moreover, the isolated channel design reduces ground loop influence during temperature measurement in distributed machinery monitoring installations.\u003c\/p\u003e\n\u003cp\u003eThis proTIM-R module supports thermal condition measurement for rotating equipment components through Platinum RTD inputs. In addition, the module architecture follows Bently Nevada monitoring practices that maintain measurement integrity for machinery diagnostics, including sensor signal scaling and verification methods used in condition monitoring systems.\u003c\/p\u003e\n\u003cp\u003eThe module operates within the Trendmaster platform where temperature data contributes to machinery protection analysis. Furthermore, the hardware design supports separation between field sensor wiring and system communication paths to reduce signal interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of sensors can the Bently Nevada 200200-03-03-05 accept?\u003cbr\u003eA: The module accepts 2-wire or 3-wire Platinum RTD temperature sensors, typically configured with Pt100 resistance elements.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 200200-03-03-05 provide isolated temperature inputs?\u003cbr\u003eA: Yes. The module provides isolated temperature input channels to reduce electrical interference and ground loop effects between field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be installed on a standard industrial DIN rail?\u003cbr\u003eA: Yes. The module uses a 35 mm DIN rail mounting configuration for installation inside industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 200200-03-03-05 module on a properly secured 35 mm DIN rail inside an enclosure that meets the environmental requirements of the installation location.\u003c\/p\u003e\n\u003cp\u003eConnect RTD sensor wiring according to the selected 2-wire or 3-wire configuration. Use shielded instrumentation cable where required, and terminate cable shields according to the plant grounding standard to minimize electrical noise.\u003c\/p\u003e\n\u003cp\u003eSeparate RTD signal cables from high-voltage power conductors, motor cables, and switching circuits. Additionally, verify terminal connections before system startup to prevent incorrect temperature readings caused by wiring errors.\u003c\/p\u003e\n\u003cp\u003eConfirm communication wiring between the proTIM-R module and the Trendmaster network before commissioning. Therefore, perform signal verification using the system configuration software to validate channel assignment and temperature measurement response.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44375406510168,"sku":"200200-03-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/200200-03-03-05-3.jpg?v=1784009938","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-200200-03-03-05-temperature-interface-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}