{"product_id":"bently-nevada-143729-01-cylinder-pressure-i-o-module","title":"Bently Nevada 143729-01 Cylinder Pressure I\/O Module","description":"\u003ch2\u003eBently Nevada 143729-01 Cylinder Pressure I\/O Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 143729-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e143729-01\u003c\/strong\u003e Cylinder Pressure I\/O Module, operates as a dedicated hardware component for cylinder pressure signal acquisition within Bently Nevada machinery monitoring systems. It processes analog pressure inputs and provides conditioned output signals for combustion and reciprocating equipment analysis.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e143729-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCylinder Pressure I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19 x 18 x 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e0-95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 5 g RMS per ISO 10816\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC +\/-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAnalog 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth\u003c\/td\u003e\n\u003ctd\u003eDC to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of Shipment\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Shipping Size\u003c\/td\u003e\n\u003ctd\u003e19 x 18 x 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Processing and Rotor Dynamics Interface\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 143729-01 module handles cylinder pressure measurement signals through analog conditioning circuits designed for machinery diagnostic applications. The module supports voltage and current input channels, including 4-20 mA instrumentation signals, and converts measured pressure data into standardized analog outputs.\u003c\/p\u003e\n\u003cp\u003eMoreover, the module operates with measurement characteristics required for reciprocating machinery analysis, where pressure waveform accuracy affects combustion evaluation and mechanical condition monitoring. Signal bandwidth up to DC to 20 kHz supports dynamic pressure acquisition, while the 16-bit or higher resolution improves measurement granularity.\u003c\/p\u003e\n\u003cp\u003eThe module design follows Bently Nevada machinery monitoring practices, including signal integrity management for sensor interfaces. Input conditioning reduces measurement interference during high-vibration operation, while calibrated signal processing supports consistent pressure data interpretation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal types does the 143729-01 support?\u003cbr\u003eA: The module supports voltage inputs of +\/-10 V and 0-5 V, as well as 4-20 mA current input signals.\u003c\/p\u003e\n\u003cp\u003eQ: What power supply does the 143729-01 require?\u003cbr\u003eA: The module requires a 24 VDC power supply with a tolerance of +\/-10% and typical power consumption below 10 W.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental conditions support module operation?\u003cbr\u003eA: The module operates from -40 deg C to +85 deg C with 0-95% RH non-condensing humidity and vibration resistance up to 5 g RMS per ISO 10816.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 143729-01 module in a controlled industrial enclosure that maintains the specified operating temperature and humidity limits. Use appropriate grounding practices to minimize electrical noise on analog signal circuits.\u003c\/p\u003e\n\u003cp\u003eRoute pressure sensor wiring separately from high-current power cables and switching circuits. Connect cable shields according to the system grounding design to reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eVerify the 24 VDC supply polarity before energizing the module. Confirm input signal scaling and analog output calibration during commissioning to ensure correct pressure measurement data transmission.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44356732878936,"sku":"143729-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/143729-01-3.jpg?v=1783663401","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-143729-01-cylinder-pressure-i-o-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}