{"product_id":"bently-nevada-141377-01-isolator-terminal-base","title":"Bently Nevada 141377-01 Isolator Terminal Base","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 141377-01 Isolator Terminal Base\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eConfigured for electrical isolation between vibration transducers and monitoring modules in the 1701\/06 vibration monitoring system, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 141377-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e141377-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIsolator Terminal Base) provides direct physical\/electrical execution of signal separation and ground loop suppression within sensor termination architecture.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo validated functional suffix segmentation is defined for this order number.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e141377-01: Isolator Terminal Base identifier used within 1701\/06 system configuration indexing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo additional functional suffix logic provided in the source dataset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e141377-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e127 x 203 x 508 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (no active power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 (1 per sensor\/transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections\u003c\/td\u003e\n\u003ctd\u003eScrew terminals, 12–22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5%–95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eThermoplastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Isolation and Transducer Interface Integrity in Vibration Monitoring Systems\u003c\/h3\u003e\n\u003cp\u003eThe module operates as a passive isolation termination element within the vibration measurement chain. It enforces galvanic separation between vibration transducer inputs and downstream monitoring electronics, preventing ground loop formation across sensor return paths.\u003c\/p\u003e\n\u003cp\u003eWithin rotor dynamics measurement chains, the isolator terminal base supports stable eddy-current probe wiring topology by maintaining defined reference separation between signal return and system ground. This reduces susceptibility to cross-talk propagation in multi-channel vibration acquisition racks, particularly where long sensor lead routing is present.\u003c\/p\u003e\n\u003cp\u003eThe absence of active circuitry ensures that signal conditioning remains external to the terminal base, preserving raw transducer output integrity prior to conditioning stages in the 1701\/06 monitoring architecture.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 141377-01 require external power for operation?\u003cbr\u003eA: No. The module is a passive terminal base and does not consume electrical power.\u003c\/p\u003e\n\u003cp\u003eQ: Can the isolator maintain channel separation under mixed high-voltage and low-voltage routing conditions?\u003cbr\u003eA: Yes, provided wiring separation rules are maintained and high-voltage conductors are physically isolated from signal terminals.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module hot-swappable during system operation?\u003cbr\u003eA: It is not intended for live removal. System power isolation is required before mechanical disconnection to avoid signal interruption.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount on a properly grounded DIN rail to maintain shielding reference stability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure torque compliance on screw terminals for 12–22 AWG conductors to avoid intermittent contact resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute transducer signal cables separately from high-voltage conductors to minimize induced noise coupling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain full seating of terminal contacts across all 6 channels to preserve channel isolation integrity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify system grounding topology before energizing connected monitoring modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44295410810968,"sku":"141377-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/141377-012.jpg?v=1782805462","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-141377-01-isolator-terminal-base","provider":"IndustriaX Limited","version":"1.0","type":"link"}