{"product_id":"bently-nevada-135183-01-3500-temperature-monitor-module","title":"Bently Nevada 135183-01 3500 Temperature Monitor Module","description":"\u003ch2\u003eBently Nevada 135183-01 3500 Temperature Monitor Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 135183-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e135183-01\u003c\/strong\u003e 3500 Temperature Monitor Module, operates as a dedicated hardware component for RTD temperature signal acquisition and monitoring within the Bently Nevada 3500 Machinery Protection System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e135183-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTemperature Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003e3500 Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 mm x 24.4 mm x 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLess than 4.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 independent RTD input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003ePt100, Pt1000, Ni120 RTD sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Wiring\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, and 4-wire RTD configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Current\u003c\/td\u003e\n\u003ctd\u003e1 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003eGreater than 1 MOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-200 deg C to +600 deg C depending on RTD type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003eTypical +\/-0.5 deg C with 3-wire or 4-wire RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Configuration\u003c\/td\u003e\n\u003ctd\u003eDual programmable Alert and Danger alarms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Function\u003c\/td\u003e\n\u003ctd\u003eLatching alarm operation with reset requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Tool\u003c\/td\u003e\n\u003ctd\u003e3500 Rack Configuration Software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Processing and Temperature Monitoring Integration\u003c\/h3\u003e\n\u003cp\u003eThe 135183-01 module processes RTD temperature inputs through the 3500 system backplane and provides channel-based monitoring logic for machinery temperature protection. The module supports independent alarm configuration for each measurement channel and transfers temperature status data to the rack controller.\u003c\/p\u003e\n\u003cp\u003eFor Bently Nevada monitoring architectures, temperature measurement is coordinated with machinery protection functions including rotor dynamics analysis and condition monitoring. The module operates alongside vibration and position monitoring hardware where temperature changes can affect bearing clearance, lubrication conditions, and mechanical operating parameters.\u003c\/p\u003e\n\u003cp\u003eThe 3500 platform maintains signal integrity through controlled input processing and channel isolation techniques. System configuration allows engineers to define alarm thresholds, measurement ranges, and monitoring logic according to the installed RTD sensor characteristics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What type of temperature sensors can be connected to the Bently Nevada 135183-01?\u003cbr\u003eA: The module accepts RTD temperature sensors including Pt100, Pt1000, and Ni120 types with 2-wire, 3-wire, or 4-wire connection methods.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 135183-01 provide independent alarm settings for each input channel?\u003cbr\u003eA: Yes. Each of the 16 RTD input channels supports separate programmable Alert and Danger alarm thresholds through 3500 configuration software.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 135183-01 configured through the 3500 rack software environment?\u003cbr\u003eA: Yes. Module parameters, alarm limits, and monitoring settings are configured through the standard 3500 Rack Configuration Software.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 135183-01 module in an available slot of the Bently Nevada 3500 rack following the approved rack configuration procedure.\u003c\/p\u003e\n\u003cp\u003eRTD field wiring should use suitable shielded instrumentation cables where required by the installation environment. Cable routing should avoid high-current power lines and electromagnetic interference sources.\u003c\/p\u003e\n\u003cp\u003eFor 3-wire and 4-wire RTD connections, maintain correct terminal identification to prevent lead resistance compensation errors. Verify sensor polarity, cable continuity, and grounding conditions before system commissioning.\u003c\/p\u003e\n\u003cp\u003eAfter installation, confirm module communication status through the 3500 configuration software and verify temperature input values against the connected RTD sensor characteristics.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44350281384024,"sku":"135183-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/135183-01-3.jpg?v=1783591165","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-135183-01-3500-temperature-monitor-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}