{"product_id":"bently-nevada-122407-01-rtd-input-and-record-terminal-module","title":"Bently Nevada 122407-01 RTD Input and Record Terminal Module","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eBently Nevada 122407-01 RTD Input and Record Terminal Module\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eConfigured for sensor termination and alarm signal routing in the 3300 Series Monitoring System, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 122407-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e122407-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRTD Input and Record Terminal Module) provides direct physical\/electrical execution of RTD interface wiring, recorder output routing, and alarm relay terminal aggregation across rack-mounted machinery protection architectures.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eNo structured suffix segmentation is defined for model 122407-01. The identifier represents a fixed 3300 Series terminal module configuration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e122407-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (loop powered via monitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eRTD sensors, pressure transducers, vibration sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eAlarm relay outputs, recorder outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Functions\u003c\/td\u003e\n\u003ctd\u003eTemperature, pressure, overspeed, vibration, position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5–95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eRack-mounted modular terminal interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBently Nevada RTD Lead Resistance Compensation and Signal Integrity Behavior\u003c\/h3\u003e\n\u003cp\u003eThe 122407-01 module is positioned at the termination layer of RTD measurement chains within 3300 Series racks. RTD input wiring is routed through shielded conductors to minimize lead-wire resistance influence on temperature conversion accuracy. The module does not perform active signal conditioning; compensation is handled at the monitoring module level.\u003c\/p\u003e\n\u003cp\u003eIn multi-channel measurement topologies, separation of RTD and relay wiring paths reduces induced coupling from adjacent alarm output switching events. Shield termination practices are required to maintain stable resistance-to-temperature conversion under variable EMI\/RFI field conditions. Improper grounding introduces offset drift due to common-mode interference across long RTD lead runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 122407-01 provide internal signal conditioning for RTD inputs?\u003cbr\u003eA: No. It functions as a passive termination interface. RTD excitation and linearization are performed in the associated 3300 Series monitor module.\u003c\/p\u003e\n\u003cp\u003eQ: Can alarm relay outputs share the same wiring harness as RTD inputs?\u003cbr\u003eA: No. Relay outputs generate switching transients that can induce noise into low-level RTD measurement circuits. Separate routing is required.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module compatible with 3500 Series systems?\u003cbr\u003eA: No. The electrical and mechanical interface is designed specifically for 3300 Series rack architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module must be installed in a compatible 3300 Series rack slot with verified mechanical seating across all backplane contacts before energization. RTD wiring should use twisted, shielded pairs with single-point grounding at the control cabinet reference plane.\u003c\/p\u003e\n\u003cp\u003eRelay output wiring must be segregated from low-level sensor wiring to avoid inductive coupling during switching events. Shield continuity should be maintained across cable glands and terminated according to standard industrial grounding topology practices.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44296100741208,"sku":"122407-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/122407-012.jpg?v=1782807207","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-122407-01-rtd-input-and-record-terminal-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}