{"product_id":"bently-nevada-102242-00-05-50-vibration-transmitter","title":"Bently Nevada 102242-00-05-50 Vibration Transmitter","description":"\u003ch2\u003eBently Nevada 102242-00-05-50 Vibration Transmitter \/ Piezoelectric Accelerometer\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 102242-00-05-50\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e102242\u003c\/strong\u003e Vibration Transmitter \/ Piezoelectric Accelerometer, operates as a dedicated hardware component for converting machine vibration signals into standardized analog outputs for industrial condition monitoring networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e102242-00-05-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter \/ Piezoelectric Accelerometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 500 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered, supplied through 4-20 mA current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Variable\u003c\/td\u003e\n\u003ctd\u003eVibration velocity or acceleration (configuration-dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sensitivity\u003c\/td\u003e\n\u003ctd\u003eTypically 100 mV\/g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Method\u003c\/td\u003e\n\u003ctd\u003eDirect stud mounting on machine or bearing housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Vibration Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 102242 series is designed for direct measurement of mechanical vibration behavior from rotating equipment. The transmitter processes vibration acceleration signals through an integrated piezoelectric sensing element and converts the measured condition into a proportional 4-20 mA output.\u003c\/p\u003e\n\u003cp\u003eThe device supports vibration analysis requirements associated with rotor dynamics evaluation, including monitoring of unbalance, shaft misalignment, bearing degradation, and mechanical looseness. Signal conditioning is performed within the transmitter assembly to provide a standardized interface for PLC, DCS, and SCADA input channels.\u003c\/p\u003e\n\u003cp\u003eFor systems using Bently Nevada machinery protection architectures, vibration transmitter installation practices should consider sensor mounting stiffness, mechanical resonance effects, cable routing separation, and signal integrity requirements. Proper grounding and shielding practices reduce electrical interference during low-level vibration signal transmission.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 102242-00-05-50 connect directly to a PLC or DCS analog input channel?\u003cbr\u003eA: Yes. The transmitter provides a 4-20 mA loop-powered output that can be connected directly to compatible analog input channels without requiring a separate proximity monitoring rack.\u003c\/p\u003e\n\u003cp\u003eQ: What type of mechanical faults can be detected through this vibration transmitter?\u003cbr\u003eA: The measured vibration signal can be used for identifying conditions such as rotor unbalance, coupling misalignment, bearing wear, and mechanical looseness when integrated with appropriate monitoring logic.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factors affect vibration measurement accuracy?\u003cbr\u003eA: Measurement accuracy depends on correct mechanical mounting, proper sensor contact with the machine housing, suitable cable routing, and appropriate grounding and shielding of the signal loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter directly onto the monitored machine structure or bearing housing using a rigid mechanical mounting method.\u003c\/li\u003e\n\u003cli\u003eEnsure the mounting surface is clean and free from contamination that could affect vibration transfer.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables separately from high-current power cables and variable frequency drive output wiring to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the plant grounding standard and avoid creating unintended ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify the 4-20 mA loop wiring polarity before applying operating power.\u003c\/li\u003e\n\u003cli\u003eConfirm the transmitter output response through the control system analog input channel after installation.\u003c\/li\u003e\n\u003cli\u003ePerform vibration baseline recording after commissioning to establish normal operating conditions for future condition monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44341245280344,"sku":"102242-00-05-50","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/102242-00-05-50-3.jpg?v=1783417473","url":"https:\/\/www.industriaxplc.com\/ar\/products\/bently-nevada-102242-00-05-50-vibration-transmitter","provider":"IndustriaX Limited","version":"1.0","type":"link"}