{"product_id":"ao810v2-3bse038415r1-abb-s800-i-o-analog-output-module","title":"AO810V2 3BSE038415R1  ABB S800 I\/O Analog Output Module","description":"\u003ch2\u003eABB AO810V2 3BSE038415R1 Analog Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for unipolar analog current output in the ABB S800 I\/O platform, the \u003cstrong\u003eABB AO810V2 3BSE038415R1\u003c\/strong\u003e (\u003cstrong\u003eAO810V2\u003c\/strong\u003e Analog Output Module) provides eight output channels for transmitting 0-20 mA or 4-20 mA control signals. It supports ABB AC 800M controllers and ABB 800xA automation systems while providing cyclic diagnostics for output circuitry and communication with the D\/A converters.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAO810V2 3BSE038415R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eAO810V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE038415R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eEstimated shipping size: 4.5 x 10.5 x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.3 W power dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eUnipolar analog current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder\/Over Range\u003c\/td\u003e\n\u003ctd\u003e- \/ +15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e0.35 ms at PL = 500 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Cycle Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus Current Consumption\u003c\/td\u003e\n\u003ctd\u003eMax 70 mA at +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Current Consumption\u003c\/td\u003e\n\u003ctd\u003e245 mA at +24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eS800 I\/O Signal Processing and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe AO810V2 uses eight analog output channels to generate 0-20 mA or 4-20 mA signals. Each channel provides a unipolar current output for direct connection to compatible field devices.\u003c\/p\u003e\n\u003cp\u003eThe module reads back serial data from the D\/A converters and verifies the returned data. Therefore, communication faults between the module logic and D\/A conversion circuitry can be detected during operation.\u003c\/p\u003e\n\u003cp\u003eIn addition, the module performs cyclic self-diagnostics. It supervises the process power supply and reports insufficient supply voltage to the output circuitry as a channel error.\u003c\/p\u003e\n\u003cp\u003eChannel diagnostics also detect output-current faults on active channels. Specifically, the module reports an error when the measured output current falls below the configured output value while that output value exceeds 1 mA.\u003c\/p\u003e\n\u003cp\u003eThe 14 bit resolution supports discrete analog signal conversion, while the specified update cycle remains at or below 2 ms. Furthermore, the 600 meter maximum field cable length provides the stated installation limit for field signal wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog output channels does the AO810V2 provide?\u003cbr\u003eA: The AO810V2 provides 8 unipolar analog output channels.\u003c\/p\u003e\n\u003cp\u003eQ: Which output current ranges does the module support?\u003cbr\u003eA: The module supports 0-20 mA and 4-20 mA output signals.\u003c\/p\u003e\n\u003cp\u003eQ: What electrical current does the module draw from its supplies?\u003cbr\u003eA: The module consumes a maximum of 70 mA from the +5 V Modulebus supply and 245 mA from the +24 V external supply.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the AO810V2 according to the applicable ABB S800 I\/O hardware installation requirements.\u003c\/li\u003e\n\u003cli\u003eVerify the module identity and terminal-unit configuration before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003eUse field cables suitable for analog current transmission and keep signal wiring separated from high-voltage and high-current conductors.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified maximum field cable length of 600 meters.\u003c\/li\u003e\n\u003cli\u003eConnect the 0-20 mA or 4-20 mA circuits according to the configured channel function and field-device requirements.\u003c\/li\u003e\n\u003cli\u003eApply the specified grounding and shielding practice for the installation environment. Avoid unintended shield connections that can introduce ground-current paths.\u003c\/li\u003e\n\u003cli\u003eVerify the +5 V Modulebus and +24 V external supply connections before commissioning.\u003c\/li\u003e\n\u003cli\u003eAfter energization, check module and channel diagnostics. In particular, investigate channel errors associated with insufficient process supply or output-current deviation.\u003c\/li\u003e\n\u003cli\u003eConfirm the analog output value at the field device before placing the associated control loop into service.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623761866840,"sku":"AO810V2 3BSE038415R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AO810V2-3BSE038415R1-3_1200x1200_1655fecb-4be2-4ee1-87ce-8f5b795dba36.jpg?v=1787130487","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ao810v2-3bse038415r1-abb-s800-i-o-analog-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}