{"product_id":"anb10d-425-yokogawa-esb-bus-node-unit","title":"ANB10D-425 Yokogawa ESB Bus Node Unit","description":"\u003ch2\u003eYokogawa ANB10D-425 ESB Bus Node Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa ANB10D-425\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eANB10D\u003c\/strong\u003e ESB Bus Node Unit, operates as a dedicated hardware component for analog and discrete signal interfacing within CENTUM VP and CENTUM CS 3000 Distributed Control Systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa ANB10D-425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e10 kg (fully populated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e482.6 mm x 221.5 mm x 150.6 mm (W x H x D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 50 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e230 VA \/ 120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConfiguration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (2 independent power supply modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputVoltage\u003c\/td\u003e\n\u003ctd\u003e220 to 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplyFrequency\u003c\/td\u003e\n\u003ctd\u003e50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOModuleSlots\u003c\/td\u003e\n\u003ctd\u003eUp to 8 FIO modules per node unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaxConnectableUnits\u003c\/td\u003e\n\u003ctd\u003eUp to 13 per FCU (depending on model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBusConnection\u003c\/td\u003e\n\u003ctd\u003eESB Bus via EC401 \/ EC402 Coupler Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSupports \u003cstrong\u003e4-20 mA HART loop protocol\u003c\/strong\u003e for analog I\/O channels.\u003c\/li\u003e\n\u003cli\u003eProvides \u003cstrong\u003echannel-to-channel isolation\u003c\/strong\u003e to minimize signal interference.\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity\u003c\/strong\u003e for field device integration.\u003c\/li\u003e\n\u003cli\u003eIncludes \u003cstrong\u003ecold junction compensation (CJc)\u003c\/strong\u003e for thermocouple signal accuracy across environmental temperature variations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eQ: Does the ANB10D-425 support hot-swapping of FIO modules?\u003cbr\u003eA: No, the FIO modules must be powered down before insertion or removal to avoid bus communication errors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum backplane current load per node unit?\u003cbr\u003eA: Each node unit supports standard FIO module loads; the total should not exceed the rated 120 W consumption to maintain stable operation.\u003c\/p\u003e\n\u003cp\u003eQ: Can firmware updates be applied while the unit remains connected to the FCU?\u003cbr\u003eA: Firmware updates require the ESB node to be isolated from live bus communication to ensure safe flash programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField Installation Guidelines\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit on a \u003cstrong\u003estandard 19-inch rack\u003c\/strong\u003e using M5 x 4 screws; ensure mechanical stability.\u003c\/li\u003e\n\u003cli\u003eMaintain \u003cstrong\u003eproper grounding of the ESB bus shield\u003c\/strong\u003e to prevent EMI interference.\u003c\/li\u003e\n\u003cli\u003eRoute power and signal cables separately where possible to minimize cross-talk.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive bending or compression of backplane connectors during installation.\u003c\/li\u003e\n\u003cli\u003eIf configured as the last node on the bus chain, use the \u003cstrong\u003e\/CU2T Connector Unit with terminator\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44187002044504,"sku":"ANB10D-425","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ANB10D-425-2.jpg?v=1780625546","url":"https:\/\/www.industriaxplc.com\/ar\/products\/anb10d-425-yokogawa-esb-bus-node-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}