{"product_id":"allen-bradley-slc-500-1492-aifm8-3-analog-interface-module","title":"Allen-Bradley 1492-AIFM8-3 Analog Interface Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 1492-AIFM8-3 is an 8-channel feed-through Analog Interface Module (AIFM) designed to simplify field wiring for PLC analog I\/O systems. This module serves as a bridge between field devices and the controller, providing a clean, organized termination point that reduces the need for external terminal blocks and jumper accessories. It features 3 terminals per input channel, allowing for efficient signal, common, and shield connections.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel feed-through design for streamlined analog signal management.\u003c\/li\u003e\n\u003cli\u003e3 terminals per input channel to support signal, common, and shield wiring.\u003c\/li\u003e\n\u003cli\u003eIntegrated power bus with eight extra terminals jumpered together for common or power supply distribution.\u003c\/li\u003e\n\u003cli\u003eInternal jumpering to the D-shell housing for effective shield grounding.\u003c\/li\u003e\n\u003cli\u003eCompatible with various PLC analog I\/O cards, facilitating faster panel assembly and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis interface module is widely used in industrial control panels where high-density analog I\/O is required. It is commonly deployed with Allen-Bradley SLC 500 and ControlLogix systems to interface with sensors, transmitters, and actuators, ensuring reliable signal integrity and simplified troubleshooting.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1492-AIFM8-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals per Channel\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e0 – 132 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e2 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 – 95 % RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the AIFM securely on a standard DIN rail within the control cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify that the field-side wiring does not exceed the rated voltage and current specifications of the module.\u003c\/li\u003e\n\u003cli\u003eUtilize the commoned power bus terminals for efficient distribution of common or power supply lines.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding by connecting the shield terminals as required by the specific I\/O module pinout.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate spacing for ventilation to ensure the module operates within the specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the 1492-AIFM8-3?\u003c\/h3\u003e\u003cp\u003eThe 1492-AIFM8-3 is an 8-channel analog interface module that provides 3 terminals per channel, supporting 16 single-ended points or 8 differential points, simplifying panel wiring by consolidating connections for faster installation.\u003c\/p\u003e\u003ch3\u003eCan it handle 16 single-ended channels?\u003c\/h3\u003e\u003cp\u003eYes, it supports 16 single-ended analog points by providing shared common and shield terminals, allowing for 16 inputs or outputs using the 3-terminal-per-channel configuration.\u003c\/p\u003e\u003ch3\u003eIs this product brand new?\u003c\/h3\u003e\u003cp\u003eYes, the 1492-AIFM8-3 is supplied as a new, original, and factory-sealed unit.\u003c\/p\u003e\u003ch3\u003eDo you provide a warranty?\u003c\/h3\u003e\u003cp\u003eWe provide a full 12-month warranty for this module, covering any defects from the date of delivery.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":44652602556504,"sku":"1492-AIFM8-3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_4b949730-f1be-4ebb-9650-9cffc861e720.jpg?v=1787589752","url":"https:\/\/www.industriaxplc.com\/ar\/products\/allen-bradley-slc-500-1492-aifm8-3-analog-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}