{"product_id":"allen-bradley-1769-ia16-compactlogix-input-module","title":"Allen Bradley 1769-IA16 CompactLogix Input Module","description":"\u003ch2\u003eAllen Bradley 1769-IA16 CompactLogix Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in industrial automation networks, the \u003cstrong\u003eAllen Bradley 1769-IA16\u003c\/strong\u003e (\u003cstrong\u003e1769-IA16\u003c\/strong\u003e Input Module) provides direct physical and electrical execution. Operating as a robust hardware component, this unit acquires up to 16 AC input signals, processing industrial voltage levels effectively while ensuring system integrity across controller backplanes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1769-IA16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (Standard Factory Origin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 lbs (0.34 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard CompactLogix 1769 Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C (32 deg F to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e115 mA at 5.1 VDC (Backplane current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Category\u003c\/td\u003e\n\u003ctd\u003e100\/120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e79-132V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Inputs (Internally Connected Commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Delays\u003c\/td\u003e\n\u003ctd\u003e20 ms On \/ 20 ms Off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Heat Dissipation\u003c\/td\u003e\n\u003ctd\u003e3.3 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module integrates seamlessly into the CompactLogix system architecture, utilizing high-speed backplane bus communication to transfer acquired data packets directly to the central processor. Furthermore, firmware flash compatibility ensures that the hardware can receive internal code updates via RSLogix 5000 or Studio 5000 environment toolsets without requiring physical component replacements. Consequently, the internal scanning mechanism operates deterministically, matching the backplane cycle to maintain tight tolerances on input state detection across all sixteen channels simultaneously.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 1769-IA16 module support live insertion and removal under power (hot-swapping)?\u003c\/p\u003e\n\u003cp\u003eA: No. Users must disconnect power from the module and the chassis backplane before installing or removing the 1769-IA16 to prevent electrical arcing and backplane bus corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is power supplied to the internal logic circuitry of this input module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws its internal logic power directly from the 5.1 VDC and 24 VDC rails of the CompactLogix system backplane, consuming approximately 115 mA at 5.1 VDC.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that the CompactLogix system power is completely isolated before mounting the 1769-IA16 module onto the DIN rail or panel mount. Secure the module latch firmly to lock it into position adjacent to the controller or previous I\/O module. Subsequently, connect field wiring to the removable terminal block (RTB), ensuring that wire stripping lengths comply with manufacturer specifications. Verify that AC supply lines fall strictly within the 79-132V AC operating voltage range before energizing the circuit. Finally, ground the system chassis and enclosure in accordance with local electrical codes to mitigate electromagnetic interference (EMI) and safeguard against transient surge voltages.\u003c\/p\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":44591353331800,"sku":"1769-IA16","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/1769-IA16-3_1200x1200_26dfb8a0-fed4-4569-bd37-91540eadcde5.jpg?v=1786607691","url":"https:\/\/www.industriaxplc.com\/ar\/products\/allen-bradley-1769-ia16-compactlogix-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}