{"product_id":"ai825-3bse036456r1-abb-s800-i-o-analog-input-module","title":"AI825 3BSE036456R1 ABB S800 I\/O Analog Input Module","description":"\u003ch2\u003eABB AI825 3BSE036456R1 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB AI825 3BSE036456R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAI825\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for bipolar current and voltage signal acquisition within ABB S800 I\/O systems. The module provides 4 individually galvanic isolated input channels with selectable current or voltage measurement functions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI825 3BSE036456R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e45 mm W x 102 mm D x 119 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTyp. 2.5 W, Max. 3.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE036456R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Specification\u003c\/td\u003e\n\u003ctd\u003e-20 to +20 mA, 0(4) to 20 mA, -10 to +10 V, 0(2) to 10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSOE Support\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 bit plus sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 MOhm voltage input, 50 Ohm current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIndividually isolated channel-to-channel and to circuit common\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnder\/Over Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Error\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Rise Time\u003c\/td\u003e\n\u003ctd\u003e115 ms voltage input, 130 ms current input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Cycle Time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Cable Length\u003c\/td\u003e\n\u003ctd\u003e600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMRR\u003c\/td\u003e\n\u003ctd\u003e120 dB at 50 Hz and 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMRR\u003c\/td\u003e\n\u003ctd\u003eGreater than 40 dB at 50 Hz, greater than 55 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e1900 VDC channel-to-channel, 3250 VDC channel-to-ground\/system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +5 V\u003c\/td\u003e\n\u003ctd\u003eTyp. 70 mA, Max. 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModuleBus Current Consumption +24 V\u003c\/td\u003e\n\u003ctd\u003eTyp. 90 mA, Max. 110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal +24 V Consumption\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible MTU\u003c\/td\u003e\n\u003ctd\u003eTU811, TU813, TU831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Code\u003c\/td\u003e\n\u003ctd\u003eDA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 I\/O Backplane and Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe AI825 uses ABB S800 I\/O architecture with ModuleBus power conversion from the 24 V supply. Each input channel maintains individual galvanic isolation, which separates field signals from adjacent channels and the internal circuit common.\u003c\/p\u003e\n\u003cp\u003eThe module supports direct current measurement inputs with overvoltage protection. The current input circuit uses a PTC resistor for current limitation, while the voltage input stage withstands up to 6.3 V input levels. Therefore, the module can process mixed field signals without external signal conditioning.\u003c\/p\u003e\n\u003cp\u003eThe S800 platform provides structured I\/O density scaling through the ModuleBus interface. The AI825 supports deterministic communication between the I\/O module and ABB controller platforms through the S800 I\/O communication structure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the AI825 support HART communication for smart field devices?\u003cbr\u003eA: No. The AI825 is a standard analog input module and does not provide HART protocol communication capability.\u003c\/p\u003e\n\u003cp\u003eQ: Can each AI825 input channel be configured independently?\u003cbr\u003eA: Yes. Each of the 4 channels can operate as either a voltage input or a current input with individual galvanic isolation.\u003c\/p\u003e\n\u003cp\u003eQ: What MTU units are compatible with the AI825 module?\u003cbr\u003eA: The AI825 supports TU811, TU813, and TU831 Module Termination Units with keying code DA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the AI825 module in an ABB S800 I\/O station using the specified compatible MTU. Confirm the mechanical keying position before insertion to prevent incorrect module placement.\u003c\/p\u003e\n\u003cp\u003eConnect field wiring according to the selected current or voltage input configuration. Keep analog signal cables separated from high voltage and high current conductors to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eUse proper cable shielding practices for analog signal lines. Connect shields according to the plant grounding standard and avoid creating unwanted ground loops.\u003c\/p\u003e\n\u003cp\u003eVerify ModuleBus connections and 24 V power supply quality before system commissioning. Check front LED indicators for Fault, Run, and Warning status after installation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44627724959832,"sku":"AI825 3BSE036456R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AI825-3BSE036456R1-3_1200x1200_e66794dc-7e76-4276-b5d0-d36aede9911a.jpg?v=1787216338","url":"https:\/\/www.industriaxplc.com\/ar\/products\/ai825-3bse036456r1-abb-s800-i-o-analog-input-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}