{"product_id":"agp813-s10-high-speed-protection-module-yokogawa","title":"AGP813-S10 High-Speed Protection Module | Yokogawa","description":"\u003ch2\u003eYokogawa AGP813-S10 High-Speed Protection Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYokogawa AGP813-S10\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAGP813-S10\u003c\/strong\u003e High-Speed Protection Module, operates as a dedicated hardware component for turbine control and high-speed tripping logic within CENTUM VP Distributed Control Systems. It provides isolated input\/output execution and precise sequence-of-events logging for event analysis.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa AGP813-S10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (module only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FCS module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC (ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003eMax. 900 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystemCompatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ Field Control Station (FCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScanCycle\u003c\/td\u003e\n\u003ctd\u003eHigh-speed: 5 ms \/ Basic: 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltageInputs\u003c\/td\u003e\n\u003ctd\u003e4 ch (high-speed) \/ 6 ch (basic); 1–5 VDC; ±4 mV accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulseSpeedInputs\u003c\/td\u003e\n\u003ctd\u003e0.5–150 Vpp; 50 Hz–25 kHz; ±1 Hz (50–2 kHz), ±0.05% (2–25 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigitalInputs\u003c\/td\u003e\n\u003ctd\u003e4 ch (high-speed) \/ 8 ch (basic); 24 VDC sink; 1 ms SOE resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigitalOutputs\u003c\/td\u003e\n\u003ctd\u003e4 ch (high-speed) \/ 8 ch (basic); current sinking; 100 mA max load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolationVoltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC for 1 min between system and field \/ I\/O types\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Specifics\u003c\/h3\u003e\n\u003cp\u003e\u003ci\u003eChannel-to-channel isolation:\u003c\/i\u003e Each I\/O channel maintains galvanic separation to reduce cross-talk and electromagnetic interference in DCS loops.\u003cbr\u003e\u003ci\u003e4-20 mA\/HART loop protocol compatibility:\u003c\/i\u003e Voltage inputs can interface with analog signal conditioning for process measurement.\u003cbr\u003e\u003ci\u003eCold junction compensation (CJC):\u003c\/i\u003e Ensures accuracy of temperature-related sensor signals in control calculations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AGP813-S10 module be hot-swapped while the FCS is operating?\u003cbr\u003eA: No. The module requires system power down to prevent I\/O latch-up or data corruption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum allowable load per digital output?\u003cbr\u003eA: Each channel supports up to 100 mA at 30 VDC. Exceeding this may damage the sinking circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support firmware upgrades in the field?\u003cbr\u003eA: Firmware is fixed per module; updates must be performed via Yokogawa-approved service procedures with the module offline.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module into the designated FCS rack slot with proper alignment to backplane connectors.\u003c\/li\u003e\n\u003cli\u003eEnsure field signal cables (e.g., AKB337-M005\/M007\/M010) are routed to minimize EMI pickup; maintain separation from power lines.\u003c\/li\u003e\n\u003cli\u003eConnect all sensor and digital lines using shielded twisted-pair cabling; terminate shields at a single ground point.\u003c\/li\u003e\n\u003cli\u003eVerify that isolation barriers remain intact between field wiring and module chassis to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eObserve torque specifications on terminal screws to maintain reliable electrical contact without deforming connectors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44219991851096,"sku":"AGP813-S10","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/AGP813-S10-2.jpg?v=1781149433","url":"https:\/\/www.industriaxplc.com\/ar\/products\/agp813-s10-high-speed-protection-module-yokogawa","provider":"IndustriaX Limited","version":"1.0","type":"link"}