{"product_id":"adr541-p00-yokogawa-centum-relay-output-module","title":"ADR541-P00 | Yokogawa CENTUM Relay Output Module","description":"\u003ch2\u003eYokogawa ADR541-P00 CENTUM Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for relay contact signal switching and field device actuation in CENTUM control networks, the \u003cstrong\u003eYokogawa ADR541-P00\u003c\/strong\u003e (\u003cstrong\u003eADR541\u003c\/strong\u003e Relay Output Module) provides direct electrical execution through 16 isolated relay output channels. The module supports status output, pulse width output, and time-proportioning output functions for external loads connected to the control system.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSuffix Element\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003ePulse width output function and time-proportioning output function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eWithout status display; no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Brand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum current consumption 780 mA at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eCENTUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Type\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system isolation; commons isolated in groups of 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Applied Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 110 V DC, 100 to 240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Load Capacity\u003c\/td\u003e\n\u003ctd\u003e2.0 A\/ch at 24 V DC, 0.4 A\/ch at 110 V DC, 2.0 A\/ch at 100\/220 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Load Capacity\u003c\/td\u003e\n\u003ctd\u003e0.6 A\/ch at 24 V DC, 0.1 A\/ch at 110 V DC, 1.0 A\/ch at 100\/220 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Mechanical Life\u003c\/td\u003e\n\u003ctd\u003eMinimum 100,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 12 ms (status output), \u0026lt;= 20 ms (mixed status and pulse output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Range\u003c\/td\u003e\n\u003ctd\u003e40 ms to 7200 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Width Resolution\u003c\/td\u003e\n\u003ctd\u003e8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC for 1 minute (output to system), 1.35 kV AC for 1 minute (between commons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e100 MOhm or greater at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Connections\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal or AKB334 dedicated cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe ADR541-P00 implements channel-to-system isolation while separating commons into two groups of eight channels. This arrangement reduces electrical interference between output groups and supports independent switching of external loads. The relay outputs can interface with field circuits associated with 4-20 mA control loops, HART-connected instruments, and discrete control devices through external interposing hardware where required by the application.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the ADR541-P00 directly switch both AC and DC loads?\u003cbr\u003eA: Yes. The module supports relay switching of 24 to 110 V DC loads and 100 to 240 V AC loads within the specified current ratings.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support pulse-based output functions?\u003cbr\u003eA: Yes. The ADR541-P00 provides pulse width output and time-proportioning output functions in addition to standard ON\/OFF status outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Are all 16 channels electrically independent?\u003cbr\u003eA: Channel-to-system isolation is provided, while every eight channels share a common minus side. Commons are isolated from each other.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify the applied load voltage and current remain within the relay contact ratings before wiring field devices.\u003c\/li\u003e\n\u003cli\u003eSeparate output wiring from high-energy power cables to minimize electromagnetic coupling into control circuits.\u003c\/li\u003e\n\u003cli\u003eUse the specified pressure clamp terminal or AKB334 cable assembly according to the installation design.\u003c\/li\u003e\n\u003cli\u003eConnect inductive loads using suitable suppression devices where required by site engineering standards.\u003c\/li\u003e\n\u003cli\u003eConfirm insulation resistance and field wiring continuity before energizing the module.\u003c\/li\u003e\n\u003cli\u003eEnsure cabinet grounding and shield termination practices comply with the system grounding architecture.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":44174801567832,"sku":"ADR541-P00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/ADR541-P00-3.jpg?v=1780449561","url":"https:\/\/www.industriaxplc.com\/ar\/products\/adr541-p00-yokogawa-centum-relay-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}