{"product_id":"abb-tu810-compact-module-termination-unit","title":"ABB TU810 Compact Module Termination Unit","description":"\u003ch2\u003eABB TU810 Compact Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for field-signal termination and ModuleBus distribution in the ABB S800 I\/O system, the \u003cstrong\u003eABB TU810 3BSE008524R1\u003c\/strong\u003e (\u003cstrong\u003eTU810\u003c\/strong\u003e Compact Module Termination Unit) provides the physical and electrical interface between field wiring and compatible S800 I\/O modules. The unit supports 16 signal channels with a maximum operating voltage of 50 V.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003e3BSE008524R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCompact Module Termination Unit (MTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem\u003c\/td\u003e\n\u003ctd\u003eABB S800 I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Process Connection Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size - Solid\u003c\/td\u003e\n\u003ctd\u003e0.2 to 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size - Stranded\u003c\/td\u003e\n\u003ctd\u003e0.2 to 2.5 mm2 (24 to 12 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Keying\u003c\/td\u003e\n\u003ctd\u003e2 mechanical keys, 6 positions each, 36 combinations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail mounting with integrated grounding latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20, IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApproximately 64 mm W x 64 mm D x 170 mm H, including latch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEstimated Shipping Size\u003c\/td\u003e\n\u003ctd\u003e7.6 x 7.6 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg; supplied product data lists 0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eStandard ABB S800 single I\/O modules, including AI810, DI810, DO810 and AO810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModuleBus Distribution and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe TU810 terminates field wiring and distributes the ModuleBus to the installed I\/O module. It also passes the ModuleBus onward to the next MTU in the rack. The unit generates the required module position address by shifting the outgoing position signals.\u003c\/p\u003e\n\u003cp\u003eThe 16-channel termination arrangement provides a defined physical connection point for compatible S800 I\/O modules. Mechanical keying uses two keys with six selectable positions each, providing 36 possible combinations to restrict insertion to the configured module type.\u003c\/p\u003e\n\u003cp\u003eThe TU810 functions as a passive termination unit; therefore, the supplied technical data does not specify a separate power-consumption value for the MTU itself. Module power requirements depend on the installed S800 I\/O module and system configuration.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the TU810 provide active I\/O signal processing?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The TU810 is a passive Module Termination Unit. It provides field-signal termination, ModuleBus distribution, position-signal handling and mechanical keying for the associated S800 I\/O module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum voltage and current specified for the TU810?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The specified maximum voltage is 50 V. The maximum current per I\/O channel is 2 A, while the maximum process connection current is 5 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied data specify hot-swap or firmware compatibility for the TU810?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied information does not define a hot-swap procedure, firmware version compatibility, or hot-swap electrical limitations. These functions should be evaluated from the documentation for the installed S800 I\/O module and system configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU810 on the specified DIN rail and engage the integrated grounding latch correctly.\u003c\/li\u003e\n\u003cli\u003eConfirm that the mechanical key positions correspond to the intended S800 I\/O module before insertion.\u003c\/li\u003e\n\u003cli\u003eTerminate field conductors according to the permitted conductor cross-sections and the applicable S800 installation documentation.\u003c\/li\u003e\n\u003cli\u003eKeep signal wiring separated from high-current and high-noise conductors where the installation requires electromagnetic interference control.\u003c\/li\u003e\n\u003cli\u003eRoute shields and protective conductors according to the plant grounding and EMC design. Do not use signal shields as substitutes for protective earth conductors.\u003c\/li\u003e\n\u003cli\u003eVerify the field wiring against the assigned I\/O channel before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm that the connected field voltage does not exceed the specified 50 V maximum.\u003c\/li\u003e\n\u003cli\u003eInspect the ModuleBus and position-signal connections before installing the associated I\/O module.\u003c\/li\u003e\n\u003cli\u003eDo not infer hot-swap capability from the MTU construction alone; follow the applicable S800 system procedure.\u003c\/li\u003e\n\u003cli\u003eMaintain the IP20 protection characteristics by installing the unit within an appropriate protected control-panel environment.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44595716227160,"sku":"TU810","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU810-3_1200x1200_e6b891e9-079c-4781-906c-f4925f3483d0.jpg?v=1786703788","url":"https:\/\/www.industriaxplc.com\/ar\/products\/abb-tu810-compact-module-termination-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}