{"product_id":"abb-ci861k01-3bse058590r1-vip-communication-interface","title":"ABB CI861K01 3BSE058590R1 VIP Communication Interface","description":"\u003ch2\u003eABB CI861K01 VIP Communication Interface\u003c\/h2\u003e\n\u003cp\u003eConfigured for VIP communication within AC 800M controller architectures, the \u003cstrong\u003eABB CI861K01\u003c\/strong\u003e (\u003cstrong\u003eCI861\u003c\/strong\u003e VIP Communication Interface) provides the communication hardware interface supplied with the TP853 baseplate. The package is specified for AC800xA M\/PEC systems and includes the CI861 communication unit and TP853 baseplate.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI861K01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCI861\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Function\u003c\/td\u003e\n\u003ctd\u003eVIP Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003eAC800xA M\/PEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded Baseplate\u003c\/td\u003e\n\u003ctd\u003eTP853\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Width\u003c\/td\u003e\n\u003ctd\u003e60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE058590R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaced Product IDs\u003c\/td\u003e\n\u003ctd\u003e3AUA0000083933; 5FSE707630-72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden; United States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.621 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 mm x 59 mm x 127.5 mm package dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Depth \/ Length\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Height\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Width\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Order Quantity\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Multiple\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Type\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Status\u003c\/td\u003e\n\u003ctd\u003eNot RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e851762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBatteries\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB Controller Interface and Baseplate Integration\u003c\/h3\u003e\n\u003cp\u003eThe CI861K01 combines the CI861 VIP communication interface with the TP853 baseplate. Therefore, installation requires the supplied baseplate arrangement rather than treating the communication interface as an independent field wiring component.\u003c\/p\u003e\n\u003cp\u003eThe TP853 baseplate has a specified width of 60 mm. Consequently, cabinet layout must provide sufficient mechanical clearance for the complete assembly and its associated controller-side connections.\u003c\/p\u003e\n\u003cp\u003eThe supplied data identifies CI861K01 as a communication module for AC800xA M\/PEC systems. However, it does not specify communication speed, protocol frame rate, power consumption, or firmware revision requirements. These parameters should therefore be verified against the applicable ABB system documentation before configuration.\u003c\/p\u003e\n\u003cp\u003eThe product data also lists replaced product identifiers \u003cstrong\u003e3AUA0000083933\u003c\/strong\u003e and \u003cstrong\u003e5FSE707630-72\u003c\/strong\u003e. These identifiers should not be interpreted as electrical equivalents without checking the applicable hardware and software compatibility documentation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are included with the CI861K01 package?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The package includes one CI861 VIP Communication Interface and one TP853 baseplate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the specified baseplate width?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The TP853 baseplate has a specified width of 60 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied data specify power consumption or operating temperature?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The provided product information does not state either parameter, so application-specific values must be obtained from the applicable ABB technical documentation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInstall the CI861 communication interface on the specified TP853 baseplate according to the ABB hardware installation procedure.\u003c\/li\u003e\n\u003cli\u003eVerify the mechanical mounting position before energizing the AC 800M assembly. Allow clearance for connectors, wiring, and module removal.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installed controller hardware and system configuration support the CI861K01 before commissioning.\u003c\/li\u003e\n\u003cli\u003eRoute communication wiring separately from high-voltage power conductors where practical to reduce electromagnetic coupling.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate cable shielding and grounding practices according to the applicable ABB installation documentation and the plant grounding design.\u003c\/li\u003e\n\u003cli\u003eDo not apply unverified power or signal connections to the communication interface. Use the connector assignments and electrical limits specified for the installed hardware revision.\u003c\/li\u003e\n\u003cli\u003eBefore system startup, verify module seating, baseplate engagement, connector retention, and controller-side configuration.\u003c\/li\u003e\n\u003cli\u003eBecause the supplied data does not define operating temperature or power consumption, confirm these parameters from the applicable hardware manual before final cabinet thermal and power calculations.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623580069976,"sku":"CI861K01 3BSE058590R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI861K01-3BSE058590R1-3_1200x1200_c4cb0a4c-4aec-4018-8445-c38edbfdc878.jpg?v=1787127007","url":"https:\/\/www.industriaxplc.com\/ar\/products\/abb-ci861k01-3bse058590r1-vip-communication-interface","provider":"IndustriaX Limited","version":"1.0","type":"link"}