{"product_id":"abb-ci855-masterbus-300-communication-interface","title":"ABB CI855 MasterBus 300 Communication Interface","description":"\u003ch2\u003eABB CI855 MasterBus 300 Communication Interface\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI855\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI855\u003c\/strong\u003e MasterBus 300 Communication Interface, provides MB 300 communication between AC 800M controllers and existing MasterBus 300 based controllers within System 800xA installations. The interface connects to the CEX-Bus through the TP853 baseplate and supports redundant Ethernet line connections.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI855\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eMasterBus 300 Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE018106R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eABB MasterBus 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaster or Slave\u003c\/td\u003e\n\u003ctd\u003eMaster\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e10 Mbit\/s, 200 datasets\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Together with HI Controller\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units on CEX-Bus\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate\u003c\/td\u003e\n\u003ctd\u003eTP853\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eRJ-45 female, 8-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported through two Ethernet ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 150 mA at 24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN 60529 and IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certificates\u003c\/td\u003e\n\u003ctd\u003eBV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEU RoHS, UAE RoHS, CN RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e59 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e185 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e127.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Including Base\u003c\/td\u003e\n\u003ctd\u003e700 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eABB manufacturing origin not specified in the supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMasterBus 300 Communication and Industrial Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe CI855 implements ABB MasterBus 300 communication within the AC 800M controller environment. It connects through the CEX-Bus and uses the TP853 baseplate for physical installation and Ethernet network connections.\u003c\/p\u003e\n\u003cp\u003eThe interface operates as an MB 300 master and supports a transmission speed of 10 Mbit\/s with up to 200 datasets\/s. Furthermore, line redundancy supports redundant network communication, while module redundancy is not specified for the CI855.\u003c\/p\u003e\n\u003cp\u003eThe interface allows peer-to-peer communication between System 800xA plant sections using AC 800M controllers and existing MB 300 based controller sections. Supported legacy controller platforms include Advant Controller 410, Advant Controller 450, and MasterPiece 200\/1.\u003c\/p\u003e\n\u003cp\u003eFor ABB industrial control architectures, the CEX-Bus provides the local communication path between the AC 800M controller and the CI855 interface. The specified maximum is 12 units on the CEX-Bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CI855 support hot swapping?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The supplied specifications identify the CI855 as supporting hot swap operation. Site procedures should still follow the applicable AC 800M and System 800xA maintenance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CI855 provide module redundancy?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The supplied data specifies line redundancy as supported, while module redundancy is specified as not supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the CI855 connect to the MB 300 network?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The CI855 uses the TP853 baseplate, which provides two RJ-45 Ethernet connectors. The two ports support network redundancy within the MB 300 communication arrangement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TP853 baseplate on a suitable DIN rail with adequate mechanical clearance.\u003c\/li\u003e\n\u003cli\u003eInstall the CI855 onto the baseplate according to the AC 800M hardware installation procedure.\u003c\/li\u003e\n\u003cli\u003eConnect the CEX-Bus interface through the designated baseplate connection.\u003c\/li\u003e\n\u003cli\u003eUse the specified RJ-45 Ethernet interfaces for MB 300 network connections.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables separately from high-voltage and high-current power wiring where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate cable bend radius and prevent excessive mechanical loading on RJ-45 connectors.\u003c\/li\u003e\n\u003cli\u003eApply the site grounding and shielding practices specified for the System 800xA installation.\u003c\/li\u003e\n\u003cli\u003eVerify the redundant network topology before placing the CI855 into service.\u003c\/li\u003e\n\u003cli\u003eConfirm the CEX-Bus unit count remains within the specified maximum of 12 units.\u003c\/li\u003e\n\u003cli\u003eCheck ambient temperature and enclosure conditions against the specified 0 deg C to +55 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eFor corrosive environments, verify that the installation conditions remain within the stated G3 corrosion classification.\u003c\/li\u003e\n\u003cli\u003ePerform communication diagnostics after installation before connecting the interface to operational MB 300 controller sections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44623613755480,"sku":"CI855","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI855-2_1200x1200_fc58348c-d7ce-4971-936b-7403928ef226.jpg?v=1787128005","url":"https:\/\/www.industriaxplc.com\/ar\/products\/abb-ci855-masterbus-300-communication-interface","provider":"IndustriaX Limited","version":"1.0","type":"link"}