{"product_id":"abb-advant-s800-i-o-tu835v1-extended-module-termination-unit","title":"ABB Advant S800 I\/O TU835V1 Extended Module Termination Unit","description":"\u003ch2\u003eABB TU835V1 Extended Module Termination Unit\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB TU835V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eTU835V1\u003c\/strong\u003e Extended Module Termination Unit, provides field termination, ModuleBus distribution, and position-address generation for ABB S800 I\/O modules. It supports up to 8 I\/O channels with a maximum rated voltage of 50 V and maximum current of 2 A per channel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTU835V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArticle Number\u003c\/td\u003e\n\u003ctd\u003e3BSE013236R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eExtended Module Termination Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e126 mm W x 110 mm H x 64 mm D, including connector and terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 I\/O channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per I\/O Channel\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current at Process Connection\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eTerminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Direction\u003c\/td\u003e\n\u003ctd\u003eBoth directions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported I\/O\u003c\/td\u003e\n\u003ctd\u003eAI810, AI815, AI845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connections\u003c\/td\u003e\n\u003ctd\u003e16 I\/O terminals, 4 process power terminals, 4 process power 0 V terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003eSingle I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Solid\u003c\/td\u003e\n\u003ctd\u003e0.2 - 4 mm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size, Stranded\u003c\/td\u003e\n\u003ctd\u003e0.2 - 2.5 mm2, 24 - 12 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Terminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 - 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Stripping Length\u003c\/td\u003e\n\u003ctd\u003e7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 - 95 %, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to IEC 60529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003eDegree 2, IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04: G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Conditions\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4, EN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Category\u003c\/td\u003e\n\u003ctd\u003eIEC\/EN 60664-1, EN 50178\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eClass I according to IEC 61140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Mark\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Safety\u003c\/td\u003e\n\u003ctd\u003eEN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Location Approval\u003c\/td\u003e\n\u003ctd\u003eC1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarine Certification\u003c\/td\u003e\n\u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Compliance\u003c\/td\u003e\n\u003ctd\u003eEN 50581:2012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB S800 ModuleBus and Address Distribution\u003c\/h3\u003e\n\u003cp\u003eThe TU835V1 distributes the ModuleBus from the connected I\/O module to the next MTU in the installation. At the same time, it generates the appropriate I\/O module address by shifting outgoing position signals toward the next MTU.\u003c\/p\u003e\n\u003cp\u003eThe MTU supports mechanical configuration through two keys. Each key provides six positions, producing 36 possible mechanical configurations. This keying mechanism physically configures the MTU for compatible I\/O module types without changing the electrical functionality of either the MTU or I\/O module.\u003c\/p\u003e\n\u003cp\u003eThe unit supports AI810, AI815, and AI845 modules according to the supplied technical data. Therefore, the mechanical key positions should match the applicable I\/O module configuration before installation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: How many I\/O channels does the TU835V1 support?\u003c\/p\u003e\n\u003cp\u003eA: The TU835V1 supports up to 8 I\/O channels. Each channel has a maximum rated current of 2 A and a maximum rated voltage of 50 V.\u003c\/p\u003e\n\u003cp\u003eQ: How does the TU835V1 generate the I\/O module address?\u003c\/p\u003e\n\u003cp\u003eA: The MTU generates the appropriate address by shifting the outgoing position signals to the next MTU.\u003c\/p\u003e\n\u003cp\u003eQ: Does the mechanical key configuration change the electrical function of the MTU?\u003c\/p\u003e\n\u003cp\u003eA: No. The two mechanical keys provide physical configuration for different I\/O module types. The selected key positions do not change the electrical functionality of the MTU or I\/O module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the TU835V1 on a compatible standard DIN rail and verify that the mechanical latch fully locks the unit.\u003c\/li\u003e\n\u003cli\u003eRelease the DIN rail latch with a screwdriver when removing the MTU.\u003c\/li\u003e\n\u003cli\u003eConfirm that the two mechanical keys match the intended I\/O module configuration before installation.\u003c\/li\u003e\n\u003cli\u003eConnect field wiring according to the terminal assignment and supported process connections.\u003c\/li\u003e\n\u003cli\u003eKeep wiring within the specified solid and stranded conductor ranges.\u003c\/li\u003e\n\u003cli\u003eApply the specified terminal torque of 0.5 - 0.6 Nm during field wiring.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified 7 mm conductor stripping length.\u003c\/li\u003e\n\u003cli\u003eSeparate signal wiring from high-current or high-noise conductors where the installation requires electromagnetic interference control.\u003c\/li\u003e\n\u003cli\u003eRoute shields and protective earth connections according to the plant grounding design and applicable electrical installation standards.\u003c\/li\u003e\n\u003cli\u003eVerify the 50 V maximum rated voltage and 2 A maximum current per I\/O channel before energizing the circuit.\u003c\/li\u003e\n\u003cli\u003eConfirm that the ambient temperature remains within 0 to +55 deg C during operation.\u003c\/li\u003e\n\u003cli\u003eInspect the terminal connections and mechanical latch before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44612534009944,"sku":"TU835V1 3BSE013236R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/TU835V1-3BSE013236R1-3_1200x1200_1ba1decb-2d37-45b4-89b1-59e9398ddc0c.jpg?v=1786957391","url":"https:\/\/www.industriaxplc.com\/ar\/products\/abb-advant-s800-i-o-tu835v1-extended-module-termination-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}