{"product_id":"abb-ac-800m-ci869-3bse049110r1-af-100-communication-interface-module","title":"ABB AC 800M CI869 3BSE049110R1 AF 100 Communication Interface Module","description":"\u003ch2\u003eABB CI869 3BSE049110R1 AF 100 Communication Interface Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eABB CI869 3BSE049110R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI869\u003c\/strong\u003e AF 100 Communication Interface Module, operates as a dedicated hardware component for Advant Fieldbus 100 communication through twisted pair (TWP) connections within AC 800M controller platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI869 3BSE049110R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAF 100 Communication Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eABB AC 800M \/ AC 160 \/ Connectivity Server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eABB Advant Fieldbus 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Role\u003c\/td\u003e\n\u003ctd\u003eSlave station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eTwisted Pair (TWP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd\u003e1.5 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Redundancy\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot Swap\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh Integrity Controller Support\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units on CEX Bus\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e+24 VDC through CEX-Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eTypical 160 mA at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20 according to EN60529 and IEC 529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosion Protection\u003c\/td\u003e\n\u003ctd\u003eG3 compliant to ISA 71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Marking\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Compliance\u003c\/td\u003e\n\u003ctd\u003eDirective 2012\/19\/EU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e700 g including base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e59 mm W x 185 mm H x 127.5 mm D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eABB CEX-Bus and AF 100 Communication Architecture\u003c\/h3\u003e\n\u003cp\u003eThe CI869 provides the physical and logical interface between an AC 800M controller and the ABB Advant Fieldbus 100 network. The module integrates CEX-Bus communication logic, an AF 100 communication unit, and a DC\/DC converter for internal voltage distribution.\u003c\/p\u003e\n\u003cp\u003eThe module receives +24 VDC input through the CEX-Bus and supplies the required operating voltage for the communication electronics. Additionally, the integrated twisted pair modem enables direct connection to AF 100 field devices and controller stations.\u003c\/p\u003e\n\u003cp\u003eThe CI869 supports redundant cable configurations and redundant communication interface arrangements. Therefore, an AC 800M controller equipped with CI869 operates as an AF 100 station that exchanges process data with other AF 100 nodes.\u003c\/p\u003e\n\u003ch3\u003eBackplane Bus Communication and Redundancy Functions\u003c\/h3\u003e\n\u003cp\u003eThe CI869 uses ABB controller expansion architecture with CEX-Bus communication handling. The module supports communication interface redundancy and line redundancy configurations for continuous fieldbus operation.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the module supports hot swap operation, allowing replacement procedures within supported AC 800M configurations without complete system shutdown. The communication design maintains AF 100 slave station behavior while transferring data between connected control nodes.\u003c\/p\u003e\n\u003cp\u003eThe CI869 can also operate within AC 800M High Integrity systems where communication availability and controlled system behavior are required.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication protocol does the CI869 3BSE049110R1 support?\u003cbr\u003eA: The CI869 supports ABB Advant Fieldbus 100 communication through twisted pair (TWP) connections with a transmission speed of 1.5 Mbit\/s.\u003c\/p\u003e\n\u003cp\u003eQ: Does the CI869 support redundant communication configurations?\u003cbr\u003eA: Yes. The module supports both line redundancy and module redundancy functions when installed in compatible AC 800M configurations.\u003c\/p\u003e\n\u003cp\u003eQ: How is the CI869 powered inside the AC 800M system?\u003cbr\u003eA: The CI869 receives +24 VDC supply through the CEX-Bus and uses an internal DC\/DC converter to generate required operating voltages.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the CI869 module on the designated AC 800M CEX-Bus position according to the controller hardware configuration.\u003c\/p\u003e\n\u003cp\u003eVerify that the twisted pair (TWP) fieldbus wiring follows ABB fieldbus installation requirements. Maintain proper cable routing separation from high-voltage power conductors and high-frequency interference sources.\u003c\/p\u003e\n\u003cp\u003eConnect the communication shield according to the site grounding standard to minimize electrical noise coupling. Confirm that redundant fieldbus cables and redundant communication interfaces are installed according to the configured system topology.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, verify the +24 VDC supply connection, CEX-Bus communication status, and AF 100 network addressing parameters.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44627774570584,"sku":"CI869K01 3BSE049110R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/CI869K01-3BSE049110R1-3_1200x1200_90a01961-20dd-40f7-87cd-be93614e945a.jpg?v=1787217317","url":"https:\/\/www.industriaxplc.com\/ar\/products\/abb-ac-800m-ci869-3bse049110r1-af-100-communication-interface-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}