{"product_id":"abb-07kt98c-advant-controller-31-basic-unit","title":"ABB 07KT98C Advant Controller 31 Basic Unit","description":"\u003ch2\u003eABB 07KT98C Advant Controller 31 Basic Unit\u003c\/h2\u003e\n\u003cp\u003eConfigured for PLC logic execution, I\/O processing, and system communication in the ABB Advant Controller 31 (AC31) platform, the \u003cstrong\u003eABB 07KT98C GJR5253100R3260\u003c\/strong\u003e (\u003cstrong\u003e07KT98C\u003c\/strong\u003e Basic Unit) provides processor, memory, communication, and I\/O functions within the controller architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e07KT98C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Order Number\u003c\/td\u003e\n\u003ctd\u003eGJR5253100R3260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAdvant Controller 31 Basic Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eAdvant Controller 31 (AC31)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit, 120 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM\u003c\/td\u003e\n\u003ctd\u003e1 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W DC-IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003eRJ45, up to 100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Modes\u003c\/td\u003e\n\u003ctd\u003eFull duplex, half duplex, auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interfaces\u003c\/td\u003e\n\u003ctd\u003eARCNET \/ RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O\u003c\/td\u003e\n\u003ctd\u003eIntegrated analog input\/output channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Expansion\u003c\/td\u003e\n\u003ctd\u003eAC31 centralized and decentralized I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 254 mm x 102 mm x 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Backplane Communication and I\/O Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 07KT98C uses the AC31 controller architecture to exchange process data with connected I\/O modules. Ethernet provides network communication through the RJ45 interface, while ARCNET and RS-485 support serial system and peripheral connections.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the controller accepts 24 VDC digital signals and provides 24 VDC digital outputs rated at 0.5 A. The AC31 architecture also supports expansion through centralized and decentralized I\/O modules. Therefore, installation planning should account for the required I\/O density, bus topology, and communication interface allocation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What supply voltage does the ABB 07KT98C require?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification identifies a 24 VDC input supply with a stated 15 W DC-IN power figure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What Ethernet capability does the 07KT98C provide?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The unit provides an RJ45 Ethernet interface supporting speeds up to 100 Mbps, with full\/half duplex and auto-negotiation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 07KT98C expand its I\/O capacity?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The supplied data specifies expansion through AC31 centralized and decentralized I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the controller in a suitable control cabinet with adequate mechanical support and ventilation.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC supply polarity and voltage before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eRoute power wiring separately from high-current switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eSeparate communication and signal wiring from sources of significant electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate cable shielding and terminate shields according to the cabinet grounding scheme.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet, ARCNET, and RS-485 wiring against the applicable AC31 system configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm I\/O channel assignments and field wiring before applying process signals.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified operating temperature range of -20 deg C to +60 deg C.\u003c\/li\u003e\n\u003cli\u003eCheck that cabinet humidity remains within the specified 5% to 95% non-condensing range.\u003c\/li\u003e\n\u003cli\u003eInspect all terminal and connector interfaces for secure mechanical engagement before startup.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44685654917208,"sku":"07KT98C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/07KT98C-3_1200x1200_e94929b3-27a4-428b-9b67-81bfcb24b301.jpg?v=1788159058","url":"https:\/\/www.industriaxplc.com\/ar\/products\/abb-07kt98c-advant-controller-31-basic-unit","provider":"IndustriaX Limited","version":"1.0","type":"link"}