{"product_id":"88149-01-alarm-relay-outputs-assembly-module-bently-nevada","title":"88149-01 | Alarm Relay Outputs Assembly Module | Bently Nevada","description":"\u003ch2\u003eBently Nevada 88149-01 Alarm Relay Outputs Assembly Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for direct alarm relay routing in the Bently Nevada 3300 Series Machinery Protection System, the \u003cstrong\u003eBently Nevada 88149-01\u003c\/strong\u003e (\u003cstrong\u003e88149-01\u003c\/strong\u003e Alarm Relay Outputs Assembly Module) provides physical relay contact execution for monitor-generated alarm, shutdown, and trip conditions. The module functions as a rear rack-mounted interface translating internal protection logic into discrete external switching states for PLC or hardwired trip circuits.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 88149-01 is a single defined ordering part number within the Bently Nevada 3300 rear I\/O assembly family. No documented functional suffix segmentation or field-configurable model matrix is associated with this part number.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e88149-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg (approx, unboxed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAlarm Relay Outputs Assembly (Rear I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 Series Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDiscrete alarm \/ trip relay output interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Architecture\u003c\/td\u003e\n\u003ctd\u003eDependent on connected monitor module configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy Current \/ TSI Signal Interface Behavior (Bently Nevada Context)\u003c\/h3\u003e\n\u003cp\u003eWithin Bently Nevada machinery protection architectures, relay output assemblies such as the 88149-01 operate downstream of eddy-current proximity probe signal conditioning stages. Gap voltage scaling (commonly referenced around negative DC bias domains) is resolved at the monitor level, while the relay assembly executes binary state transitions derived from processed vibration and position parameters. Cross-talk suppression and rotor dynamics interpretation occur upstream, ensuring that relay actuation is strictly a deterministic representation of validated alarm logic rather than raw transducer signal behavior.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 88149-01 support hot-swap removal during system operation?\u003cbr\u003eA: The module is not designed for live insertion or removal. Backplane power and relay state integrity require rack de-energization prior to handling.\u003c\/p\u003e\n\u003cp\u003eQ: What is the relay output switching nature of the module?\u003cbr\u003eA: The assembly provides dry contact relay outputs driven by the associated 3300 monitor logic. Contact state is strictly binary (open\/closed) based on alarm conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module contain firmware or configurable logic?\u003cbr\u003eA: No embedded firmware or programmable logic is present. Functional behavior is fully dependent on the host monitoring module configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module only within compatible Bently Nevada 3300 rack assemblies. Ensure backplane connectors are aligned before insertion to prevent pin damage. Maintain shield continuity across rack grounding points to preserve signal reference integrity. Relay wiring should be routed separately from high-noise power conductors to avoid induced voltage coupling. Verify all external trip circuits are de-energized before termination to relay contacts. Torque and fastening should follow standard rack mechanical retention specifications defined by the 3300 system frame design.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44301618675800,"sku":"88149-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/88149-01-3.jpg?v=1782898289","url":"https:\/\/www.industriaxplc.com\/ar\/products\/88149-01-alarm-relay-outputs-assembly-module-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}