{"product_id":"79532-01-rtd-input-terminal-module-bently-nevada","title":"79532-01 RTD Input Terminal Module | Bently Nevada","description":"\u003ch2\u003eBently Nevada 79532-01 RTD Input Terminal Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for RTD signal termination and electrical conditioning in Bently Nevada 3300 Series Machinery Monitoring Systems, the \u003cstrong\u003eBently Nevada 79532-01\u003c\/strong\u003e (\u003cstrong\u003e79532-01\u003c\/strong\u003e RTD Input Terminal Module) provides direct physical\/electrical execution for resistance temperature detector interface within 3300\/35 RTD monitoring architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e79532-01 (PWA 82369-01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.4 kg to 1.5 kg (configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified (rack-mounted terminal assembly dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive module, not separately powered (system dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6 independent RTD input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Types\u003c\/td\u003e\n\u003ctd\u003e3-wire \/ 4-wire RTD (Pt100, Ni120 supported via system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 Series (3300\/35 RTD Monitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTSI Signal Conditioning and Channel Integrity Behavior (Bently Nevada Class)\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces with machinery protection measurement chains where RTD resistance conversion stability is maintained through controlled terminal impedance and structured wiring topology. Within Bently Nevada TSI architectures, channel separation and lead resistance compensation are handled at the monitor level, while the terminal assembly ensures stable mechanical termination for multi-wire RTD loops.\u003c\/p\u003e\n\u003cp\u003eIn systems where eddy-current probe scaling and gap voltage validation (-10 VDC reference structures in proximity measurement chains) coexist with temperature inputs, the RTD terminal assembly contributes to overall channel-to-channel isolation integrity by maintaining consistent wiring geometry and minimizing cross-coupling between adjacent sensor loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 79532-01 support hot-swap replacement within a live 3300 rack system?\u003cbr\u003eA: Hot-swap capability is determined by the host 3300 rack configuration. The terminal module itself is passive and does not contain active circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane power requirement for the 79532-01 module?\u003cbr\u003eA: The module does not consume dedicated power. Electrical loading is defined by the connected 3300\/35 monitor module, not the terminal assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Can 3-wire and 4-wire RTD configurations be mixed on the same module?\u003cbr\u003eA: Yes. Each channel supports independent wiring configuration, subject to the input requirements of the connected monitoring module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eRTD wiring shall be executed using twisted, shielded conductors routed away from high-energy switching lines and vibration signal cables. Shield termination should be implemented at a single grounded reference point to avoid ground loop formation.\u003c\/p\u003e\n\u003cp\u003eFor 3-wire configurations, lead resistance balancing must follow the monitoring system compensation method defined at the 3300\/35 input stage. For 4-wire configurations, ensure Kelvin connection integrity at the sensor interface.\u003c\/p\u003e\n\u003cp\u003eTerminal screws must be mechanically secured to maintain stable contact resistance under vibration conditions. Cable routing shall avoid sharp bends and maintain separation from high EMI sources such as VFD output conductors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44296131936344,"sku":"79532-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/79532-01-3.jpg?v=1782807804","url":"https:\/\/www.industriaxplc.com\/ar\/products\/79532-01-rtd-input-terminal-module-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}