{"product_id":"51405047-176-honeywell-cc-pcf091-network-interface-modules","title":"51405047-176 | Honeywell | CC-PCF091 Network Interface Modules","description":"\u003ch2\u003eHoneywell 51405047-176 Network Interface Modules\u003c\/h2\u003e\n\u003cp\u003eConfigured for deterministic network segmentation in Honeywell C9 control architectures, the \u003cstrong\u003eHoneywell 51405047-176\u003c\/strong\u003e (\u003cstrong\u003eCC-PCF901\u003c\/strong\u003e Control Firewall Module) provides direct physical\/electrical execution of port-level communication isolation across industrial control network boundaries. The module implements multi-port Ethernet segmentation with defined uplink aggregation within a 24 VDC powered backplane environment.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe model \u003cstrong\u003e51405047-176\u003c\/strong\u003e corresponds to a fixed-order Honeywell spare assembly designation. The base model \u003cstrong\u003eCC-PCF901\u003c\/strong\u003e is not subdivided into published suffix functional variants; no verified factory-documented decoding structure is available for further segmentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51405047-176 \/ CC-PCF901\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.5 x 16.2 x 14.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial control cabinet range (typ. 0 to 60 deg C, not officially stated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0.112 A @ 24 VDC (approx. 2.7 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePort Configuration\u003c\/td\u003e\n\u003ctd\u003e9 Ethernet ports (8 + 1 uplink)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus\u003c\/td\u003e\n\u003ctd\u003eDiscontinued by manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell Control Network Isolation Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe CC-PCF901 architecture integrates deterministic segmentation behavior using per-port traffic separation and controlled forwarding logic within Honeywell distributed control environments. Electrical design emphasizes channel-to-channel isolation between Ethernet switching domains and backplane-linked control segments, limiting propagation of non-deterministic traffic across control layers.\u003c\/p\u003e\n\u003cp\u003eThe module operates under a fixed 24 VDC supply rail and maintains consistent current draw behavior under nominal switching loads. Internal design aligns with industrial process control communication frameworks where segmentation integrity is prioritized over dynamic routing flexibility.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 51405047-176 support hot-swap replacement during operation?\u003cbr\u003eA: No confirmed hot-swap capability is documented. Replacement is typically performed under controlled cabinet power-down conditions to avoid backplane communication disruption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane communication dependency of the CC-PCF901 module?\u003cbr\u003eA: The module relies on system-integrated backplane signaling for control-plane synchronization. Loss of backplane integrity may result in port isolation state retention.\u003c\/p\u003e\n\u003cp\u003eQ: Are firmware upgrades supported on this module?\u003cbr\u003eA: No field-upgradable firmware interface is specified for this device class; functionality is fixed at factory configuration level.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module shall be installed in a grounded industrial control cabinet with standardized DIN rail or chassis mounting as defined by the Honeywell C9 hardware frame. Maintain minimum separation from high-noise switching devices and VFD cabling to reduce electromagnetic coupling into Ethernet signal pairs.\u003c\/p\u003e\n\u003cp\u003eEnsure 24 VDC supply lines are protected with appropriate overcurrent limiting and routed separately from high-energy conductors. Shield termination should be implemented at cabinet ground reference only, avoiding multiple grounding points along communication cable shields. Verify port labeling prior to energization to prevent misrouting of uplink and access ports.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44301415088216,"sku":"CC-PCF091","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/51405047-176-3.jpg?v=1782894015","url":"https:\/\/www.industriaxplc.com\/ar\/products\/51405047-176-honeywell-cc-pcf091-network-interface-modules","provider":"IndustriaX Limited","version":"1.0","type":"link"}