{"product_id":"3bse008510r1-abb-do810-16-channel-digital-output-module","title":"ABB 3BSE008510R1 DO810 Digital Output Module","description":"\u003cp\u003eThe ABB DO810 (3BSE008510R1) is a 16-channel digital output module designed for the S800 I\/O system. This module provides reliable control for field devices such as contactors, relays, and indicator lamps. It features two isolated groups of eight channels, each equipped with process voltage supervision to ensure system integrity and diagnostics.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 digital output channels (24 V DC, current sourcing).\u003c\/li\u003e\n\u003cli\u003eTwo isolated groups of 8 channels with independent process voltage monitoring.\u003c\/li\u003e\n\u003cli\u003eIntegrated Output Set to Predetermined state (OSP) functionality for safe-state management during communication loss.\u003c\/li\u003e\n\u003cli\u003eComprehensive protection including short-circuit, over-temperature, and over-voltage monitoring.\u003c\/li\u003e\n\u003cli\u003eOptical isolation barrier between field and system side.\u003c\/li\u003e\n\u003cli\u003eLED status indicators for individual output channel monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems:\u003c\/strong\u003e Sequencing fuel valves and ignition hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Control:\u003c\/strong\u003e Managing start\/stop logic for large motor starters and pump sequences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine Auxiliaries:\u003c\/strong\u003e Controlling hydraulic pumps, cooling fans, and valve actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation Automation:\u003c\/strong\u003e Interfacing with circuit breakers and isolators.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO810 (3BSE008510R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 (2 x 8 isolated groups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e10 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Continuous Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA (+5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power supply is disconnected before installing or removing the module from the ModuleBus.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry environment within an appropriately rated industrial enclosure to protect against dust and moisture.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the S800 I\/O station to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation clearance around the module to prevent overheating during operation.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for field wiring to ensure signal integrity and compliance with EMC standards.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the OSP function do on the DO810?\u003c\/h3\u003e\u003cp\u003eThe Output Set to Predetermined (OSP) function allows the module to force outputs into a pre-configured safe state if a communication error occurs or if the watchdog timer expires, preventing uncontrolled operation of field equipment.\u003c\/p\u003e\u003ch3\u003eAre the channels in the DO810 isolated?\u003c\/h3\u003e\u003cp\u003eYes, the 16 channels are divided into two isolated groups of eight. Each group features its own supervision input that reports process voltage status via the ModuleBus.\u003c\/p\u003e\u003ch3\u003eCan this module drive inductive loads?\u003c\/h3\u003e\u003cp\u003eThe DO810 includes built-in inductive load suppression components, allowing it to drive standard industrial relays and solenoids directly.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":44724815659096,"sku":"3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/wm_1_31aabe66-edd7-4169-9df4-6d498fe97a58.jpg?v=1788492735","url":"https:\/\/www.industriaxplc.com\/ar\/products\/3bse008510r1-abb-do810-16-channel-digital-output-module","provider":"IndustriaX Limited","version":"1.0","type":"link"}