{"product_id":"330901-00-32-05-02-cn-3300-nsv-proximity-probe-bently-nevada","title":"330901-00-32-05-02-CN 3300 NSv Proximity Probe Bently Nevada","description":"\u003ch2\u003eBently Nevada 330901-00-32-05-02-CN 3300 NSv Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330901-00-32-05-02-CN\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330901\u003c\/strong\u003e 3300 NSv Proximity Probe, operates as a dedicated eddy-current measurement component for shaft displacement and vibration monitoring within Bently Nevada proximity monitoring systems. It provides non-contact gap measurement through a 5 mm probe tip, integrated 0.5 m cable, and ClickLoc coaxial connection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330901-00-32-05-02-CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy-Current Proximity Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.2 inch overall case length, 5 mm tip diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied by 3300 XL NSv Proximitor sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Thread Type\u003c\/td\u003e\n\u003ctd\u003e1\/4-28 UNF-2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0.0 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature ClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e1.5 mm (60 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Scale Factor\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003e1.0 mm (40 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 10 kHz (+\/-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe DC Resistance\u003c\/td\u003e\n\u003ctd\u003e4.0 ohm +\/- 0.5 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 or 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Construction\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial cable with FEP insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd\u003eNEPSI China Ex approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics Measurement\u003c\/h3\u003e\n\u003cp\u003eThe 330901-00-32-05-02-CN uses eddy-current probe scaling characteristics to convert shaft displacement into proportional electrical signals. The probe operates with a 3300 XL NSv Proximitor and maintains a 7.87 V\/mm average scale factor across its measurement range.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the system supports rotor dynamics analysis by measuring dynamic radial vibration and static shaft position. The 1.5 mm linear range allows monitoring of mechanical movement through a stable electromagnetic sensing field.\u003c\/p\u003e\n\u003cp\u003eThe probe requires gap voltage validation during installation. Field technicians typically verify the operating gap near the -10 VDC target range at the Proximitor output to confirm correct probe positioning and signal conditioning.\u003c\/p\u003e\n\u003cp\u003eThe narrow side-view construction also reduces installation limitations in restricted mechanical locations while maintaining signal performance for small shaft targets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What Proximitor module is required for the 330901-00-32-05-02-CN probe?\u003cbr\u003eA: The probe operates with a compatible 3300 XL NSv Proximitor sensor that provides excitation power and converts the eddy-current signal into vibration and position outputs.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe measure both vibration and shaft position?\u003cbr\u003eA: Yes. The probe measures dynamic shaft displacement for vibration monitoring and static displacement for position measurement when configured with the appropriate monitoring system.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factors affect measurement accuracy?\u003cbr\u003eA: Correct probe gap adjustment, proper thread engagement, cable routing, and shield grounding practices directly affect measurement stability and signal quality.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the probe using the specified 1\/4-28 UNF mounting thread and maintain proper mechanical alignment with the monitored shaft surface.\u003c\/li\u003e\n\u003cli\u003eAdjust the probe gap according to the 3300 XL NSv system requirements and verify the gap voltage output before commissioning.\u003c\/li\u003e\n\u003cli\u003eProtect the ClickLoc coaxial connector from contamination, moisture, and mechanical stress during installation.\u003c\/li\u003e\n\u003cli\u003eRoute the integral cable away from high-current conductors and strong electromagnetic interference sources.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the monitoring system grounding design to reduce electrical noise.\u003c\/li\u003e\n\u003cli\u003eAvoid excessive bending or pulling force on the integral cable because mechanical stress can affect probe signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfirm hazardous area installation requirements when applying the CN NEPSI approval option.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44391150190680,"sku":"330901-00-32-05-02-CN","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330901-00-32-05-02-CN-3.jpg?v=1784277379","url":"https:\/\/www.industriaxplc.com\/ar\/products\/330901-00-32-05-02-cn-3300-nsv-proximity-probe-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}