{"product_id":"330709-000-060-50-02-00-3300-xl-11-mm-proximity-probe-bently-nevada","title":"330709-000-060-50-02-00 3300 XL 11 mm Proximity Probe Bently Nevada","description":"\u003ch2\u003eBently Nevada 330709-000-060-50-02-00 3300 XL 11 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330709-000-060-50-02-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330709\u003c\/strong\u003e 3300 XL 11 mm Proximity Probe, operates as a dedicated hardware component for shaft displacement and vibration signal measurement within the 3300 XL Proximity Transducer System.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330709-000-060-50-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e3300 XL 11 mm Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Proximity Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11 mm probe tip diameter, 60 mm case length, 5.0 m total probe length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 12 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Technology\u003c\/td\u003e\n\u003ctd\u003eEddy current non-contact displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e11 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM16 x 1.5 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eStandard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003eApproximately 2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e3.94 V\/mm (100 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd\u003eApproximately 2.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 8 kHz typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eAISI 4140 steel target recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Target Diameter\u003c\/td\u003e\n\u003ctd\u003e31 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Requirement\u003c\/td\u003e\n\u003ctd\u003e-17.5 VDC to -26 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy Current Measurement and Rotor Dynamics Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 330709-000-060-50-02-00 uses eddy-current sensing technology to convert shaft movement into proportional electrical signals. Therefore, the probe provides direct measurement of relative shaft vibration, radial displacement, and axial position.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 11 mm probe system uses a defined scaling characteristic of 3.94 V\/mm (100 mV\/mil). Furthermore, the Proximitor Sensor validates the probe gap condition through gap voltage measurement, where approximately -10 VDC represents the normal operating target position for the sensing circuit.\u003c\/p\u003e\n\u003cp\u003eThe 11 mm sensing tip supports increased measurement range compared with smaller diameter proximity probes. As a result, the system supports rotor dynamics analysis, shaft orbit monitoring, and machinery protection applications requiring continuous displacement feedback.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What components are required to operate the 330709-000-060-50-02-00 probe?\u003c\/strong\u003e\u003cbr\u003eA: The probe requires a compatible 3300 XL 11 mm Proximitor Sensor and extension cable to form a complete proximity transducer measurement circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What electrical principle does this proximity probe use?\u003c\/strong\u003e\u003cbr\u003eA: The probe uses eddy current technology to measure the distance between the probe tip and the conductive shaft target without physical contact.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of gap voltage validation in this system?\u003c\/strong\u003e\u003cbr\u003eA: Gap voltage validation confirms that the probe operates within the calibrated measurement range and maintains correct electrical distance from the shaft target.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the probe using the specified M16 x 1.5 mounting thread and maintain mechanical alignment with the shaft target surface.\u003c\/li\u003e\n\u003cli\u003eAdjust the probe position according to the recommended gap voltage range before connecting the monitoring channel.\u003c\/li\u003e\n\u003cli\u003eVerify the extension cable length and Proximitor Sensor configuration match the selected probe system.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing and avoid installation paths with excessive electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shielding according to the machinery monitoring system grounding practice.\u003c\/li\u003e\n\u003cli\u003eConfirm signal polarity, gap voltage, and output scaling before placing the protection channel into service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44433525407832,"sku":"330709-000-060-50-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330709-000-060-50-02-00-3.jpg?v=1784792509","url":"https:\/\/www.industriaxplc.com\/ar\/products\/330709-000-060-50-02-00-3300-xl-11-mm-proximity-probe-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}