{"product_id":"3300-xl-8-mm-proximity-probe-bently-nevada-330103-03-09-10-02-00","title":"3300 XL 8 mm Proximity Probe | Bently Nevada | 330103-03-09-10-02-00","description":"\u003ch2\u003eBently Nevada 330103-03-09-10-02-00 3300 XL 8 mm Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eConfigured for shaft displacement and vibration measurement in the 3300 XL 8 mm Proximity Transducer System, the \u003cstrong\u003eBently Nevada 330103-03-09-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330103\u003c\/strong\u003e 3300 XL 8 mm Proximity Probe) provides direct eddy-current sensing execution for mechanical position monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330103-03-09-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3300 XL 8 mm Eddy Current Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied by compatible 3300 XL Proximitor Sensor system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Lead Length\u003c\/td\u003e\n\u003ctd\u003e1.0 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Type\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eMiniature Coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd\u003ePolyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Body Material\u003c\/td\u003e\n\u003ctd\u003eAISI 303 \/ 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 XL 8 mm Transducer System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003e4140 Steel calibration target\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003eWithin +\/- 0.025 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 Hz DC to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e75 ohm coaxial system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Rating\u003c\/td\u003e\n\u003ctd\u003eSealed to 50 psi differential pressure across tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards Compliance\u003c\/td\u003e\n\u003ctd\u003eAPI 670 mechanical configuration and temperature stability requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy Current Signal Scaling and Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 330103-03-09-10-02-00 uses an eddy-current measurement principle to convert probe gap variation into proportional electrical output. Therefore, the probe maintains a nominal scale factor of 200 mV\/mil for shaft displacement analysis.\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe architecture supports gap voltage validation with compatible Proximitor Sensor modules. During commissioning, technicians verify the operating gap position against the -10 VDC target reference used in Bently Nevada vibration monitoring systems.\u003c\/p\u003e\n\u003cp\u003eFurthermore, the probe supports rotor dynamics analysis by providing DC position and AC vibration signals. The non-contact sensing structure allows measurement of radial vibration, axial position, Keyphasor applications, and rotating equipment shaft behavior.\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector and probe construction reduce mechanical signal interruption caused by vibration environments. In addition, the probe design maintains signal integrity through controlled coaxial transmission characteristics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What system accepts the 330103-03-09-10-02-00 probe output?\u003cbr\u003eA: The probe operates with the Bently Nevada 3300 XL 8 mm Proximitor Sensor system and requires a compatible extension cable and monitoring module configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe measure both static position and dynamic vibration signals?\u003cbr\u003eA: Yes. The eddy-current probe provides both DC gap position measurement and AC dynamic displacement measurement for shaft monitoring applications.\u003c\/p\u003e\n\u003cp\u003eQ: What installation factors affect measurement accuracy?\u003cbr\u003eA: Probe mounting position, target surface condition, cable routing, connector locking, and correct gap voltage adjustment affect signal accuracy.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the probe with the specified M10 x 1 mounting thread and maintain mechanical alignment between the probe tip and rotating shaft target surface.\u003c\/p\u003e\n\u003cp\u003eRoute the coaxial cable away from high-current power conductors and electromagnetic interference sources. Maintain proper connector engagement and verify the ClickLoc locking mechanism after installation.\u003c\/p\u003e\n\u003cp\u003eBefore operation, confirm the probe gap voltage through the connected Proximitor Sensor. Adjust the installation position to achieve the required measurement range and verify stable output during machine rotation.\u003c\/p\u003e\n\u003cp\u003eAvoid mechanical impact on the PPS probe tip and protect the cable from excessive bending or pulling forces during installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44467133972568,"sku":"330103-03-09-10-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330103-03-09-10-02-00-3.jpg?v=1785134352","url":"https:\/\/www.industriaxplc.com\/ar\/products\/3300-xl-8-mm-proximity-probe-bently-nevada-330103-03-09-10-02-00","provider":"IndustriaX Limited","version":"1.0","type":"link"}