{"product_id":"3300-16-12-01-02-00-02-00-vibration-monitor-module-bently-nevada","title":"3300\/16-12-01-02-00-02-00 Vibration Monitor Module Bently Nevada","description":"\u003ch1\u003eBently Nevada 3300\/16-12-01-02-00-02-00 Vibration Monitor Module\u003c\/h1\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16-12-01-02-00-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16 Dual Vibration Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilized to execute dual-channel vibration measurement and alarm processing across the Bently Nevada 3300 Machinery Monitoring System platforms.\u003c\/p\u003e\n\u003cp\u003eThe module processes two independent Proximitor-based vibration inputs, performs signal conditioning, and generates proportional analog outputs and relay-based alarm logic for each channel.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-12-01-02-00-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3300 rack module standard form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperatingTemp\u003c\/td\u003e\n\u003ctd\u003e0 degC to 65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePowerConsumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDual channel Proximitor transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mils peak-to-peak (Option 12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 8 mm, 3300XL 8 mm, 7200 5 mm\/8 mm systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA or 1-5 VDC recorder outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Function\u003c\/td\u003e\n\u003ctd\u003eIndependent Alert and Danger per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed output relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003e2X trip multiply function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% of full scale at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy Current Probe Scaling and Signal Integrity Behavior\u003c\/h3\u003e\n\u003cp\u003eConfigured for mechanical displacement conversion using eddy-current proximity systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/16\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses raw gap voltage variations typically centered around negative DC bias levels near -10 VDC excitation reference conditions. The internal signal chain applies linear scaling to convert probe gap modulation into engineering units of vibration amplitude (mils or micrometers).\u003c\/p\u003e\n\u003cp\u003eCross-talk suppression is implemented at the channel isolation stage to reduce electrical interference between adjacent monitoring paths within the 3300 backplane architecture. This ensures stable amplitude tracking during high-density rack operation where multiple vibration channels coexist.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the 3300\/16 module channels operate independently during a single channel fault condition?\u003cbr\u003eA: Yes. Each channel is electrically isolated with independent signal conditioning and alarm logic execution. A failure in one channel does not interrupt the second channel processing path.\u003c\/p\u003e\n\u003cp\u003eQ: What is the behavior of trip multiply activation during overspeed conditions?\u003cbr\u003eA: The trip multiply function temporarily scales alarm setpoints by a factor of 2. It is implemented at the alarm comparison stage without altering raw vibration signal scaling.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement under powered rack conditions?\u003cbr\u003eA: The module is designed for rack-based insertion; however, removal or insertion under power may induce transient signal interruption on connected channels and is not intended for continuous monitoring operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe module must be installed into a compatible Bently Nevada 3300 rack slot with full backplane seating engagement. Ensure that all Proximitor sensor cabling is routed with controlled impedance and separated from high-voltage switching conductors.\u003c\/p\u003e\n\u003cp\u003eShield termination should be grounded at a single rack-side point to prevent ground loop formation. Maintain consistent channel labeling alignment between field wiring terminals and module channel numbering.\u003c\/p\u003e\n\u003cp\u003eVerify that external barrier configurations (if used) are matched to intrinsic safety requirements before energizing sensor loops. After installation, perform zero-state validation to confirm stable gap voltage baseline and absence of channel drift.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":44244805976152,"sku":"3300\/16-12-01-02-00-02-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/2039\/0488\/files\/330016-12-01-02-00-02-00-2.jpg?v=1781573344","url":"https:\/\/www.industriaxplc.com\/ar\/products\/3300-16-12-01-02-00-02-00-vibration-monitor-module-bently-nevada","provider":"IndustriaX Limited","version":"1.0","type":"link"}